Final Checks; Care And Maintenance - Carrier Infinity 48XL Installation Instructions Manual

15 seer single packaged air condotioner and gas furnace system with puron (r-410a) refrigerant
Hide thumbs Also See for Infinity 48XL:
Table of Contents

Advertisement

THERMISTOR
CURVE
9O
I
I
I
I
80- k---- 4------ 4----- _------ 4-------I
....
\
i
i
i
i
i
7o- -'_-- q------
I----- _------
T------I ....
6o- _ _X__ J ._ _ _ .I_ _ _ __ _ _ J_ _ _ _I....
\i
i
i
i
i
50 ....
'_------
1----- _------
1-------I ....
40- -
/_.__
l______/___l
....
I\
I
I
I
I
30 .... _----_'-Z_----
_------ I----- --I ....
20
....
_ __ ____/'_._/__
____/ ____--I....
I
I
_
I
I
lo....
H---
t---_--_--
o ..................
I...................
I...................
I...................
I...................
I,,-,_
0
20
40
60
80
100
120
TEMPERATURE
(DEG. F)
A91431
Fig. 25 - Resistance
Values
Versus Temperature
THERMISTOR
SENSOR
COMPARISON
The control
continuously
monitors
and compares
the outdoor
air
temperature
sensor
and outdoor
coil temperature
sensor
to ensure
proper operating
conditions.
The comparison
is:
• In cooling
mode,
if the outdoor
air sensor
indicates
-> 10 °F
(-12°C)
warmer
than the coil sensor (or) the outdoor
air sensor
indicates
-> 20 °F cooler than the coil sensor,
the sensors
are out of
range.
>
o
,_o
• In heating
if the outdoor
air sensor indicates
_ 35 F (_ C)
warmer
than the coil sensor (or) the outdoor
air sensor indicates
-> 10°F (-12°C)
cooler than the coil sensor,
the sensors
are out
of range.
If the sensors
are out of range, the control will flash the appropriate
fault code as shown
in Table 5.
The thermistor
comparison
is not performed
during
low ambient
cooling
operation.
FAILED
THERMISTOR
DEFAULT
OPERATION
Factory
defaults
have
been
provided
in the event
of failure
of
outdoor
air thermistor
and/or coil thermistor.
If the OAT sensor
should
fail, low
ambient
cooling
will not be
allowed
and the one-minute
outdoor
fan off delay will not occur.
Defrost will be initiated
based on coil temperature
and time.
If the OCT
sensor
should
fail, low ambient
cooling
will not be
allowed.
Defrost
will occur
at each time interval
during
heating
operation,
but will terminate
after 5 minutes.
If there is a thermistor
out of range
error, defrost
will occur
at each
time interval
during
heating
operation,
but will terminate
after 5
minutes.
Refer
to the
Troubleshooting
Chart
(Table
10)
for
additional
troubleshooting
information.
_
tight on the liquid
"tub
\
J
g
Fig. 26 - Outdoor
Coil Thermistor
(OCT)
Attachment
o
F
A06311
FINAL
CHECKS
IMPORTANT:
Before leaving
job, be sure to do the following:
1. Ensure
that all wiring
is routed
away from tubing
and sheet
metal edges to prevent
rub-through
or wire pinching.
2. Ensure
that all wiring
and tubing
is secure
in unit before
adding
panels
and covers.
Securely
fasten
all panels
and
covers.
3. Tighten
service
valve
stem
caps
to l/2-turn
past
finger
tight.
4. Leave Users Manual
with owner.
Explain
system
operation
and periodic
maintenance
requirements
outlined
in manual.
5. Fill out
Start-Up
Checklist
located
at the back
of this
manual
and place in customer
file.
CARE
AND
MAINTENANCE
For
continuing
high
performance
and
to
minimize
possible
equipment
failure, periodic
maintenance
must be performed
on this
equipment.
Frequency
of maintenance
may vary depending
upon geographic
areas,
such
as
coastal
applications.
See
Users
Manual
for
information.
32