Ambient Temperature
Ambient Humidity
Environ-
Ambient Illuminance
mental
Degree of Protection (IEC 60529)
Vibration Resistance (IEC 61496-1)
Shock Resistance (IEC 61496-1)
Pollution Degree (IEC 60664-1)
Power cable
Cascading cable
Connec-
tions
Extension cable
- Single-ended cable
- Double-ended cable
Extension of Power Cable
Material
Weight (packaged)
Material
Included Accessories
Conforming standards
Type of ESPE (IEC 61496-1)
Performance Level
(PL)/Safety category
Conformity
PFHd
Proof test interval T
M
SFF
HFT
Classification
Operating
-10 to 55°C (14 to 131°F) (non-icing)
Storage
-25 to 70°C (-13 to 158°F)
Operating
35% to 85% (non-condensing)
Storage
35% to 95%
Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
IP65 and IP67
10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
2
100 m/s
, 1000 shocks for all 3 axes
Pollution Degree 3
Type of Connection
M12 connectors: 5-pin emitter and 8-pin receiver, IP67 rated when mated, Cables prewired to the sensors
Number of Wires
Emitter: 5, Receiver: 8
Cable Length
0.3 m
Cable Diameter
6 mm
Minimum Bending
R5 mm
Radius
Type of Connection
M12 connectors: 5-pin emitter and 8-pin receiver, IP67 rated when mated
Number of Wires
Emitter: 5, Receiver: 8
Cable Length
0.2 m
Cable Diameter
6 mm
Minimum Bending
R5 mm
Radius
Type of Connection
M12 connectors: 5-pin emitter and 8-pin receiver, IP67 rated when mated
Number of Wires
Emitter: 5, Receiver: 8
Cable Length
Refer to page 3.
Cable Diameter
6.6 mm
Minimum Bending
R36 mm
Radius
100 m max.
Housing: Aluminum
Cap: PBT
Front window: PMMA
Cable: Oil resistant PVC
Mounting Bracket: ZDC2
FE plate: SUS
Refer to page 8.
Safety Precautions, Quick Installation Manual, Standard Fixed Bracket*, Troubleshooting Guide
Sticker, Warning Zone Label
* The quantity of Standard Fixed Brackets included varies depending on the protective height.
[F3SG- RA
- Protective height of 0160 to 1200: 2 sets
- Protective height of 1280 to 2080: 3 sets
[F3SG- RA
- Protective height of 0190 to 1230: 2 sets
- Protective height of 1310 to 2270: 3 sets
- Protective height of 2350 to 2510: 4 sets
Refer to page 19.
Type 4
Type 4
PL e/Category 4 (EN ISO 13849-1:2008)
1.1 × 10
-8
(IEC 61508)
Every 20 years (IEC 61508)
99% (IEC 61508)
1 (IEC 61508)
Type B (IEC 61508-2)
F3SG-4RA
-14
-14]
-30]
F3SG-RA
F3SG-4RA
-30
7