Standard Muting Mode with four Muting Sensors using NPN Outputs
The following is the example of External Device Monitoring enabled, Auto Reset mode, NPN output and External Test in 0 V Active.
DIP Switch settings *3
EDM Enabled
Receiver
Auto Reset (factory default setting)
NPN
Emitter
External Test: 0 V Active
Configure functions with the DIP Switches before wiring.
Wiring Example
B1
Reflector
Muting
Sensor
A1
(NPN
output)
*1.Also used as Override input line.
*2.Make sure to connect an override cancel switch to the Reset line when
using the override function. Otherwise the override state maynot be
released by the override cancel switch, resulting in serious injury.
*3.The functions are configurable with DIP Switch. Refer to Safety Light
Curtain F3SG-R Series User's Manual for more information on setting
the functions by the DIP Switch.
18
Function
F39-JG @ A-L
F39-JG @ A-D
S1
S2
S3
*2
KM1
KM2
B2
A2
DIP-SW1
DIP-SW2
2
ON
2
3
ON
3
4
ON
4
7
ON
7
4
ON
: Indicates a switch position.
ML
KM1
KM2
+24 VDC
Power Supply
0 VDC
S1: Test Switch (Connect the line to 24 V if this switch is
not required)
S2: Override Cancel Switch
S3: Lockout/Interlock Reset Switch or Override Switch
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
or magnetic contactor
M: 3-phase motor
ML: Muting lamp
A1, A2, B1, B2: Muting sensor
Unblocked
Beam state
Blocked
Test Switch (S1)
MUTE A
MUTE B
OSSD
ON
ON
ON
ON
KM1
KM2
M