Omron F3SG-RA Manual page 24

Safety light curtain
Hide thumbs Also See for F3SG-RA:

Advertisement

F3SG-RA with Y-Joint Plug/Socket Connector in Standard Muting Mode/Exit-Only
Muting Mode using PNP outputs
The following is the example of External Device Monitoring disabled, Auto Reset mode, PNP output and External Test in 24 V Active.
DIP Switch settings *5
EDM Disabled (factory default setting)
Receiver
Auto Reset (factory default setting)
PNP (factory default setting)
Emitter
External Test: 24 V Active (factory default setting)
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-GCNY2
F39-JG@B-L
S1
*2
S1: Lockout/Interlock Reset Switch,
Override Switch or Override Cancel Switch
ML: Muting Lamp
*1.Also used as EDM input line.
*2.Make sure to connect an override cancel switch to the Reset
line when using the override function. Otherwise the override
state may not be released by the override cancel switch,
resulting in serious injury.
*3.Refer to page 29 for more information.
*4.The safety controller and the F3SG-R must share the power
supply or be connected to the common terminal of the power
supply.
*5.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual for more
information on setting the functions by the DIP Switch.
Function
F39-JG@A-D
ML
IN1
Safety
Controller *3 *4
DIP-SW1
DIP-SW2
2
ON
2
3
ON
3
4
ON
4
7
ON
7
4
ON
: Indicates a switch position.
+24V DC
Power supply
0V
IN2
Unblocked
Beam state
Blocked
MUTE A
MUTE B
OSSD
F3SG-RA
ON
ON
ON
ON
23