Standard Muting Mode/Exit-Only Muting Mode using PNP Outputs
The following is the example of External Device Monitoring disabled, Auto Reset mode, PNP output and External Test in 24 V Active.
DIP Switch settings *6
EDM Disabled (factory default setting)
Receiver
Auto Reset (factory default setting)
PNP (factory default setting)
Emitter
External Test: 24 V Active (factory default setting)
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG@A-L
S1
S1: Test Switch (Connect the line to 0 V if this switch
is not required)
S2: Lockout/Interlock Reset Switch,
Override Switch
or Override Cancel Switch
ML: Muting lamp
*1.Also used as Override input line.
*2.Make sure to connect an override cancel switch to the Reset
line when using the override function. Otherwise the override
state may not be released by the override cancel switch,
resulting in serious injury.
*3.Refer to page 29 for more information.
*4.The safety controller and the F3SG-R must share the power
supply or be connected to the common terminal of the power
supply.
*5.Refer to Smart Muting Actuator F3W-MA Series User's Manual
for more information.
*6.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual for more
information on setting the functions by the DIP Switch.
Function
F39-JG @ A-D
S2
*2
Muting
Actuator *5
Beam state
DIP-SW1
DIP-SW2
2
ON
2
3
ON
3
4
ON
4
7
ON
7
4
ON
: Indicates a switch position.
ML
IN1
IN2
Safety
Controller *3 *4
Unblocked
Blocked
Test Switch (S1)
MUTE A
MUTE B
OSSD
F3SG-RA
ON
ON
ON
ON
+24 VDC
Power Supply
0 VDC