Omron F3SG-RA Manual page 15

Safety light curtain
Hide thumbs Also See for F3SG-RA:

Advertisement

F3SG-RA
Standard Muting Mode/Exit-Only Muting Mode using NPN Outputs
The following is the example of External Device Monitoring enabled, Auto Reset mode, NPN output and External Test in 0 V Active.
DIP Switch settings *3
EDM Enabled
Receiver
Auto Reset (factory default setting)
NPN
Emitter
External Test: 0 V Active
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG@A-L
S1
S1: Test Switch (Connect the line to 24 V if this switch is not required)
S2: Override Cancel Switch
S3: Lockout/Interlock Reset Switch or Override Switch
S4, S5: Muting sensor
KM1, KM2: Safety relay with forcibly guided
contacts (G7SA) or magnetic contactor
M: 3-phase motor
ML: Muting lamp
14
Function
F39-JG @ A-D
S3
S2
S4
*2
KM1
KM2
Unblocked
Beam state
Blocked
Test Switch (S1)
MUTE A
MUTE B
OSSD
DIP-SW1
2
ON
3
ON
4
ON
7
ON
4
ON
: Indicates a switch position.
ML
KM1
KM2
S5
*1.Also used as Override input line.
*2.Make sure to connect an override cancel switch to the Reset line
when using the override function. Otherwise the override state may
not be released by the override cancel switch, resulting in serious
injury.
*3.The functions are configurable with DIP Switch. Refer to Safety
Light Curtain F3SG-R Series User's Manual for more information on
setting the functions by the DIP Switch.
DIP-SW2
2
ON
3
ON
4
ON
7
ON
KM1
KM2
+24 VDC
Power Supply
M
0 VDC