Connections (Basic Wiring Diagram)
Standalone F3SG-RA using PNP Outputs
The following is the example of External Device Monitoring enabled, Manual Reset mode, PNP output and External Test in 24 V Active.
DIP Switch settings *2
EDM Enabled
Receiver
Manual Reset
PNP (factory default setting)
Emitter
External Test: 24 V Active (factory default setting)
Configure functions with the DIP Switches before wiring.
Wiring Example
F39-JG@A-L
S1
+24 VDC
Power Supply
0 VDC
Note: The wiring examples in later pages do not indicate functional earth. To use functional earth, wire an earth cable according to the example
above. Refer to Safety Light Curtain F3SG-R Series User's Manual for more information.
Function
F39-JG@A-D
S2
KM1
KM2
S1: Test Switch (Connect the line to 0 V
if this switch is not required)
S2: Lockout/Interlock Reset Switch
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
or magnetic contactor
M: 3-phase motor
*1.Also used as EDM input line.
*2.The functions are configurable with DIP Switch. Refer to
Safety Light Curtain F3SG-R Series User's Manual for more
information on setting the functions by the DIP Switch.