1. Hopper Cleaning Entry Sub Cycle
Locate the keypad UI on the store side of the unit.
Flip the access door down to locate programming button (refer figure 8).
Press and hold the programming button then press and hold the pour/
cancel button. Keep pressing both for 5 seconds to start the cleaning
process.
All of the LED lights will light for 1 second. Then, the first light to the left
(L1) will flash.
NOTE:A 30 second timer will start. If no buttons are pressed, the
user interface will automatically cancel the cleaning process and it
will return to normal operation mode.

2. Empty the Ice Hopper

Ensure that the ice collection trays are under both of the ice dispense
chutes.
Press the pour/cancel button to start the ice dispense. L1 LED will become
illuminated (See Figure 11).
Press the pour/cancel button to pause or restart the ice dispensing as the
ice collection trays are filled.
Press the up arrow in the programming area when the hopper is empty.
3. Hopper Cleaning Cycle
L2 LED will start flashing, signaling that it is ready to proceed to the next
step.
Remove the collection trays.
Place the funnel under both of the ice dispense chutes.
© 2014-2015, Cornelius Inc.
HD Tower Dispenser Operator's Manual
- 9 -
Figure 8
Figure 9
Figure 10
Figure 11
Ice
Chute
Place
funnel
here
Figure 12