2.SPECIFICATION

2.1 Performance data of Swimming Pool Heat Pump Unit

REFRIGERANT : R410A
UNIT
Rated Heating Power Input
Range
Rated Running Current Input
Range
Power Supply
Compressor Quantity
Compressor
Fan Quantity
Fan Power Input
Fan Rotate Speed
Fan Direction
Noise
Water Connection
Water Flow Volume
Water Pressure Drop(max)
Unit Net Dimensions(L/W/H)
Unit Ship Dimensions(L/W/H)
Net Weight
Shipping Weight
Rated Heating: *Outdoor air temp: 27℃/24.3℃, Inlet water temp:26.7℃
During heating: Running ambient temperature: -5℃~43℃.
Model
HP50AEE
kW
2.68
kW
0.2-2.68
A
12.0
A
1.1-12.0
V/Hz
208-230V~/60Hz
rotary
W
RPM
500-650
horizontal
dB(A)
43-53
1.5''
inch
3
m
/h /gpm
4.1/18.5
kPa/psi
4.3/ 0.62
1048×442×770/ 41.2×17.4×30.3 1165×485×870/ 45.9×19.1×34.3
mm/ in
1130×460×780/ 44.5×18.1×30.7 1210×510×880/ 47.6×20.1×34.6
mm/ in
kg
kg
1
1
100
see nameplate
see package label
HP70AEE
3.86
0.31-3.86
16.9
1.5-16.9
208-230V~/60Hz
1
rotary
1
100
300-750
horizontal
42-57
1.5''
6.2/ 27.3
4.9/ 0.71
2

Advertisement