Signal Name & Cable Characteristics; Introduction; Rs-232 Bus; Table A-1: Lru Version/Release Definitions - L3 CP-2500 Installation Manual

Table of Contents

Advertisement

Signal Name & Cable Characteristics
A.1 INTRODUCTION
This appendix defines Digital Interface Label information and electrical characteristics of input and
output signals to the CP-2500 Control Panel. Sufficient data is included to perform an electrical load
analysis for the aircraft.
Connection information identifies the connector-pin and signal names as they appear on the external
interconnect wiring diagram shown in the installation section.
A.1.1 RS-232 BUS
The RS-232 Bus is configured as follows:
Baud rate: 9600 baud
Start Bits: 1
Data length: 8 bits
Stop Bits: 1
Parity: None
Flow Control: None
INTERFACING UNIT
(LRU)
NGT-1000
NGT-2000/-2500
NGT-1000
NGT-2000/-2500
NGT-1000/-2000/-2500
NGT-9000R
NGT-9000R
NGT-9000R
0040-17251-01
Revision D
CP-2500
Installation Manual
Appendix A

Table A-1: LRU Version/Release Definitions

HARDWARE
RELEASE
VERSION
VERSION
Version 1
Release (Rel) 1
Version 1
Release (Rel) 1
Version 1
Release (Rel) 2
Version 1
Release (Rel) 2
Version 2
Release (Rel) 2
N/A
Release (Rel) 1
N/A
Release (Rel) 2
N/A
Release (Rel) 3
Appendix A
DEFINITION
INDICATOR FROM
LRU BYTE 13
SW Release 1.0,
0 = Appliance Rel 1
1.1
SW Release 1.0,
0 = Appliance Rel 1
1.1, 1.2, or 1.3
SW Release 1.52
2 = Appliance Rel 2
and greater
SW Release 1.52
2 = Appliance Rel 2
and greater
SW Release
2 = Appliance Rel 2
1.51, 1.6, and
greater
SW Release 1.0,
1 = NGT-9000R Rel 1
1.1, 1.2
SW Release 2.0,
3 = NGT-9000R Rel 2
2.1
SW Release 3.0
4 = NGT-9000R Rel 3
and greater
DISCRETE
VALUE
Page A-1
March 15, 2018

Advertisement

Table of Contents
loading

Table of Contents