Tighten all screws to snug (i.e. only such torque that can be applied by hand) unless specific
torque instructions are given.
After installation, refer to the Installation Checkout section for ground testing procedures.
2.
Electrical equipment chassis and shield/ground terminations must be electrically bonded to the
aircraft's main structure (metallic aircraft) or instrument panel (composite aircraft). Compliance of
the electrical bonding should be verified by inspection using a calibrated milliohm meter or an
equivalent OEM procedure.
The electrical bond should achieve direct current (DC) resistance less than or equal to 2.5 m to
structure local to where the equipment is mounted for metallic aircraft or tube and fabric aircraft.
The electrical bond should achieve direct current (DC) resistance less than or equal to 5.0 m to
the instrument panel for composite aircraft.

2.3.1 Location

The CP-2500 should be mounted in the instrument panel slightly below and in close proximity with the
pilot's normal line of view, with the controls within easy reach. In selecting a location, consider the
following:
1.
The CP-2500 should be accessible for inspection, maintenance, or removal and free from instrument
panel structural flexure and excessive vibration or heat.
2.
Compare the space requirements of the CP-2500 with the installation area being considered.
The CP-2500 with part numbers 9080-17250-01 & -02 mount in a 2 ¼ inch standard round
instrument hole. Refer to Figure 2-1. Outline dimensions are located in Figure 2-2.
The CP-2500 with part number 9080-17250-12 mounts in a 3 1/8 inch standard round
instrument hole. Refer to Figure 2-1. Outline dimensions are located in Figure 2-3.