4.4.1 Remove and Replace Procedures

Use this procedure to remove and replace the CP-2500. The instructions herein are generic in scope,
specific instructions can be found in the Aircraft Maintenance Manual (AMM), if applicable.
Removal Procedure
1.
Remove (4) mounting screws securing the control panel to the instrument panel.
2.
Remove control panel from behind instrument panel.
3.
Remove mating connector P1 from the back of the control panel.
Installation Procedure
1.
Connect mating connector P1 to control panel.
2.
Secure control panel to the same area removed from instrument panel.
3.
Secure control panel to instrument panel using (4) mounting screws.
Functional Check Procedure
1.
Refer to section 3.3 in section 3 of this manual.

4.5 DISPOSITION OF FAILED ITEMS

1.
The CP-2500 can only be repaired by an ACSS Authorized Repair Center.
2.
Contact ACSS Customer Service to obtain a Return Material Authorization (RMA). Shipping
Instructions will be provided with the RMA.
3.
If available, pack components in their original shipping container. If the original container is not
available, pack them as follows:
Do not use desiccant crystals when packaging electronic
assemblies. Since the assembly must be packed tightly, crystals
in bag form cannot be used. The use of loose crystals may cause
unnecessary damage resulting in a cleaning problem.
a.
Ensure that conductive covers/caps are installed on the exposed terminals of connector, if
applicable.
b.
The CP-2500 contains electrostatic discharge sensitive (ESDS) parts and must be wrapped in
static protective materials.
c.
Wrap with bubble pack. Secure bubble pack with reinforced tape.
d.
Place unit in a cardboard box.
e.
Wrap any accessories in tissue and place in the box. Fill spaces with bubble pack.
f.
Place an explanation letter in the box with the following information.
Your name, address, and telephone number.
Purchase order number.
Description of component including, when applicable, model and serial number.
A brief description of the reason for return.
g.
Shut box and seal with reinforced tape.
h.
Attach packing list to outside of box.
Page 4-2