2.2.8 Serial Port (J12, J13)
COM1 and COM2 can be configured for RS-232, RS-422, or RS-485. The
default definition of COM 1 and COM 2 is RS-232. To change to RS-422 or RS-
485, please refer to Section 4.4.
For RS-232, the data rate is 1.5Mbps with maximum load of 150pF. For RS-422/
RS-485, the data rate is 10Mbps with maximum load of 47pF.
The operation modes can be selected by software configuration :
Mode
0
RS-422 Full Duplex
1
Pure RS-232
2
RS-485 Half Duplex
3
RS-485 Half Duplex
4
RS-422 Full Duplex
5
Reserved
6
RS-485 Half Duplex
7
Low Power Shutdown
The pin assignments are listed in the following table :
Serial Port
1 to 2
©Vecow EIC-1000 User Manual
Description
1T/1R RS-422
3T/5R RS-232.
1T/1R RS-485, TX ENABLE Low Active
1T/1R RS-485, TX ENABLE High Active
1T/1R RS-422 with termination resistor (120 ohm)
and bias Resistor (1K ohm)
Reserved
1T/1R RS-485 with termination resistor and bias
resistor. TX ENABLE Low Active
All I/O pins are High Impedance
Pin No.
RS-232
1
DCD
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
Status
RS-422
TXD-
TXD+
RXD+
RXD-
GND
-----
-----
-----
-----
GETTING TO KNOW YOUR EIC-1000
RS-485
DATA-
DATA+
-----
-----
GND
-----
-----
-----
-----