Ethernet Protocol - ADF Web HD674-A025 User Manual

Dmx / ethernet - converter
Table of Contents

Advertisement

Industrial Electronic Devices

ETHERNET PROTOCOL

DMX
(
DMX = DMX OUT)
WRITE
WHEN
The bytes that compose the request are these:
Byte Number
If the request is correct, the bytes that compose the response are these:
ADFweb.com Srl – IT31010 – Mareno – Treviso
1
ASCII char 'E'
2
ASCII char 'D'
3
ASCII char 'M'
4
ASCII char 'X'
0 ÷ 511  Starting DMX channel in ASCII format
5 ÷ 7
8 ÷ 10
1 ÷ 512  Number of consecutive DMX channels in ASCII format
11 ÷ n+11
Value in Hex for each DMX channel
n = Number of DMX channels
Byte Number
Description
1
ASCII char 'T'
2
ASCII char 'R'
3
ASCII char 'A'
4
ASCII char 'N'
5
ASCII char 'S'
6
ASCII char 'F'
7
ASCII char 'E'
8
ASCII char 'R'
9
ASCII char ' '
10
ASCII char 'D'
11
ASCII char 'O'
12
ASCII char 'N'
13
ASCII char 'E'
14
ASCII char '!'
User Manual DMX / Ethernet - Converter
Document code: MN674-A025_ENG
Description
INFO:
www.adfweb.com
Revision 1.000 Page 20 of 30