ADF Web HD674-A006 User Manual

Profinet / modbus master – converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
PROFINET / Modbus Master – Converter
(Order Code: HD674-A006)
For Website information:
www.adfweb.com?Product=HD674-A006
For Price information:
www.adfweb.com?Price=HD674-A006
Benefits and Main Features:
Very easy to configure
Wide supply input range
Electrical isolation
Industrial temperature range:
-40°C / 105°C (-40°F / 221°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
Axis Solutions Pvt Ltd is the Authorized Distributor of
www.axisindia.in | info@axisindia.in
User Manual PROFINET / Modbus Master
Document code: MN674-A006_ENG
Page 1 of 47
For others Gateways / Bridges:
J1939 to Modbus
See also the following links:
www.adfweb.com?Product=HD67212
CANopen to Modbus
See also the following links:
www.adfweb.com?Product=HD67001
www.adfweb.com?Product=HD67002
www.adfweb.com?Product=HD67004
www.adfweb.com?Product=HD67005
For others Gateways / Bridges:
For CAN bus 2.0A and/or CAN bus 2.0B to Modbus
See also the following links:
www.adfweb.com?Product=HD67011
www.adfweb.com?Product=HD67012
www.adfweb.com?Product=HD67014
www.adfweb.com?Product=HD67015
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
in India
Revision 1.000 Page 1 of 47
(Modbus RTU)
(Modbus RTU Master)
(Modbus RTU Slave)
(Modbus TCP Master)
(Modbus TCP Slave)
(Modbus RTU Slave)
(Modbus RTU Master)
(Modbus TCP Slave)
(Modbus TCP Master)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD674-A006 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADF Web HD674-A006

  • Page 1 Revision 1.000 Page 1 of 47 Page 1 of 47 Industrial Electronic Devices User Manual Revision 1.000 English PROFINET / Modbus Master – Converter (Order Code: HD674-A006) For Website information: www.adfweb.com?Product=HD674-A006 For others Gateways / Bridges: For Price information: J1939 to Modbus www.adfweb.com?Price=HD674-A006 See also the following links: www.adfweb.com?Product=HD67212...
  • Page 2: Updated Documentation

    User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 2 of 47 Page 2 of 47 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 3 of 47 Page 3 of 47 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 4 of 47 Page 4 of 47 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 5 of 47 Page 5 of 47 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD674-A006-2-E4x-xx ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 6 of 47 Page 6 of 47 Industrial Electronic Devices Figure 1b: Connection scheme for HD674-A006-2-E7x-xx ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 7 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 7 of 47 Page 7 of 47 Industrial Electronic Devices Figure 1c: Connection scheme for HD674-A006-4-E4x-xx ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 8 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 8 of 47 Page 8 of 47 Industrial Electronic Devices Figure 1d: Connection scheme for HD674-A006-4-E7x-xx ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 9 Industrial Electronic Devices CHARACTERISTICS: The “HD674-A006” series are rugged devices used to interface Modbus devices with PROFINET network. With its particular enclosure, equipped with four fixing lugs, makes available the mounting of the device in any plane surface (horizontal, vertical, oblique).
  • Page 10: Power Supply

    POWER SUPPLY: The devices can be powered between a wide range of tensions. For more details see the two tables below. Vmin Vmax Vmin Vmax HD674-A006-Exx-xx Consumption at 24V DC: Device W/VA HD674-A006-Exx-xx Caution: Not reverse the polarity power HD674-A006-E4x-xx HD674-A006-E7x-xx Note: It is possible to use also negative tensions.
  • Page 11 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 11 of 47 Page 11 of 47 Industrial Electronic Devices LEDS: The device has got four LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 12 Page 12 of 47 Industrial Electronic Devices RS232: The connection of the RS232 in the HD674-A006-2-E4x-xx device must be made with a 3way MiniFit Female connector. The pinout of Male MiniFit connector of the board is at right side of the page.
  • Page 13 Industrial Electronic Devices RS485: The connection of the RS485 in the HD674-A006-4-E4x-xx device must be made with a 3way MiniFit Female connector. The pinout of Male MiniFit connector of the board is at right side of the page. The connection of the RS485 in the HD67-A006-4-E7x-xx device must be made with a AMP SuperSeal 1.5 Male connector.
  • Page 14 ETHERNET: The connection of Ethernet in the HD674-A006 device must be made with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps. To connect the device to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC/PLC/other is recommended the use of a cross cable.
  • Page 15 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 15 of 47 Page 15 of 47 Industrial Electronic Devices USE OF COMPOSITOR SW674-A006: To configure the Converter, use the available software that runs with Windows called SW674-A006. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 16: New Configuration / Open Configuration

    User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 16 of 47 Page 16 of 47 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “PROFINET / Modbus Master - Converter”...
  • Page 17: Software Options

    User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 17 of 47 Page 17 of 47 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 18 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 18 of 47 Page 18 of 47 Industrial Electronic Devices In the section “Advanced Functions”, it is possible to send some advanced commands to the converter in order to monitor the Modbus communication and enable/disable the Modbus requests.
  • Page 19: Set Communication

    User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 19 of 47 Page 19 of 47 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, Modbus and PROFINET. By Pressing the “Set Communication”...
  • Page 20 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 20 of 47 Page 20 of 47 Industrial Electronic Devices In the field “TimeOut (ms)” the maximum time that the converter attends for the answer from the Slave interrogated is defined; In the field “Communication Idle Time (ms)”...
  • Page 21: Set Access

    User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 21 of 47 Page 21 of 47 Industrial Electronic Devices SET ACCESS: By pressing the “Set Access” button from the main window for SW674-A006 (Fig. 2) the window “Set Modbus Access” appears. This window is divided in two parts, the "Modbus Read"...
  • Page 22 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 22 of 47 Page 22 of 47 Industrial Electronic Devices ODBUS RITE The means of the fields are: In the field “Slave ID” the address of the Modbus device to write is defined; In the field “Type”...
  • Page 23 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 23 of 47 Page 23 of 47 Industrial Electronic Devices PROFINET XML: By Pressing the “PROFINET XML” button from the main window for SW674-A006 (Fig. 2) it is possible to generate the xml file to be imported into the master PROFINET.
  • Page 24: Update Device

    User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 24 of 47 Page 24 of 47 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device;...
  • Page 25 A006 device. Note: When you receive the device, for the first time, you also have to update the Firmware in the HD674-A006 device. Warning: If Fig. 7 appears when you try to do the Update try these points before seeking assistance: Try to repeat the operations for the updating;...
  • Page 26: Advanced Functions

    Industrial Electronic Devices ADVANCED FUNCTIONS: In the HD674-A006 are implemented some advanced commands that allow to check the functioning of the converter and send some Modbus commands directly from Ethernet side. These commands can be sent directly from the SW674-A006 software, using the section “Advanced Functions” under the “Option” window.
  • Page 27 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 27 of 47 Page 27 of 47 Industrial Electronic Devices (B2) RROR UMBER Figure 9: “Advanced Functions Error Poll Number” window These section of the software allows to read number of errors received (timeout or exception) for each Modbus request defined. ADFweb.com Srl –...
  • Page 28 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 28 of 47 Page 28 of 47 Industrial Electronic Devices (B3/B4) RANSPARENT Figure 10: “Advanced Functions Transparent Mode” window These section of the software allows to enable/disable the Transparent Mode of the converter. This Mode is used to send/received some serial messages directly from UDP messages.
  • Page 29 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 29 of 47 Page 29 of 47 Industrial Electronic Devices (B5/B6) THER OMMANDS Figure 11: “Advanced Functions Other Commands” window These section of the software allows to enable/disable the Modbus polling for a specific slave (ID) and/or a single poll of the Modbus tables defined in the section “Set Access”...
  • Page 30: Advanced Commands

    ADVANCED COMMANDS: In the HD674-A006 are implemented some advanced commands that allows to check the functioning of the converter and send some Modbus commands directly from Ethernet side (they are the same commands used in “Advanced Functions” section of SW674-A006). To use them, it is necessary to send UDP messages to the port 5000.
  • Page 31 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 31 of 47 Page 31 of 47 Industrial Electronic Devices B1 command This command allows to read the status of the enabling/disabling of the Modbus polls. REQ: Byte 0 0xB1 RES: Byte 0...
  • Page 32 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 32 of 47 Page 32 of 47 Industrial Electronic Devices B2 command This command allows to see the number of errors for each Modbus poll defined in the section “Set Access”. REQ: Byte 0 0xB2...
  • Page 33 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 33 of 47 Page 33 of 47 Industrial Electronic Devices B3 command This command allows to enable the Transparent: it will be possible to send Modbus commands directly from Ethernet side. The converter will become completely transparent.
  • Page 34 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 34 of 47 Page 34 of 47 Industrial Electronic Devices B5 command This command allows to enable/disable the polling to a single Modbus slave. REQ: Byte 0 Byte 1 Byte 2 0xB5 Slave ID...
  • Page 35 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 35 of 47 Page 35 of 47 Industrial Electronic Devices B6 command This command allows to enable/disable a single poll on Modbus side. REQ: Byte 0 Byte 1 Byte 2 0xB6 Poll No...
  • Page 36 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 36 of 47 Page 36 of 47 Industrial Electronic Devices MODBUS DIAGNOSTIC OVER PROFINET: It is possible to save the Modbus Diagnostic on PROFINET array using the field “Diagnostic” of the section “Set Communication”. In this case, the status of each Modbus request defined in the section “Set Access”...
  • Page 37: Plc Configuration

    User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 37 of 47 Page 37 of 47 Industrial Electronic Devices PLC CONFIGURATION: The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the TIA Portal V12-software by Siemens.
  • Page 38 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 38 of 47 Page 38 of 47 Industrial Electronic Devices 2) Import the module in the network; connect the device to the PLC network and edit the parameters of IP, station name etc. ADFweb.com Srl –...
  • Page 39 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 39 of 47 Page 39 of 47 Industrial Electronic Devices 3) Load the configuration into the PLC. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 40: Mechanical Dimensions

    User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 40 of 47 Page 40 of 47 Industrial Electronic Devices MECHANICAL DIMENSIONS: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 41 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 41 of 47 Page 41 of 47 Industrial Electronic Devices Type A ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 42 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 42 of 47 Page 42 of 47 Industrial Electronic Devices Type B ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 43 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 43 of 47 Page 43 of 47 Industrial Electronic Devices Type C ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 44: Ordering Informations

    Page 44 of 47 Industrial Electronic Devices ORDERING INFORMATIONS: The ordering part number is formed by a valid combination of the following: HD674-A006 – x - E y z – s f Fixing lugs A: Type A B: Type B...
  • Page 45 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 45 of 47 Page 45 of 47 Industrial Electronic Devices ACCESSORIES: Order Code: AC34001 Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V AC Order Code: AC34002 Rail DIN - Power Supply 110V AC 50/60Hz –...
  • Page 46 User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 46 of 47 Page 46 of 47 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 47: Warranties And Technical Support

    User Manual PROFINET / Modbus Master Document code: MN674-A006_ENG Revision 1.000 Page 47 of 47 Page 47 of 47 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents