4. Troubleshooting
Error Trouble Shooting
SYMPTOM
Cooktop burner
flames are soft
*
blue or have
yellow tips .
*
LF
LR
C
RF
Cooktop burner
flames are mostly
RR
yellow .
NOTE: High-altitude orifice kits are available.
*
*
This document can not be used without Samsung's authorization.
DIAGNOSIS
This is normal .
Check for proper sized orifices:
NG
1 .78
1 .40
1 .38
1 .36/1 .36/0 .85
0 .83/0 .83/0 .46
1 . 0 1
Check for crimped or cracked gas line
between the pressure gas regulator and the
surface burner control manifold .
Faulty gas pressure regulator .
*
Soft blue flames are normal flames
for NG operation .
*
Soft blue flames with yellow tips are
normal flames for LP operation.
LP
1 . 0 4
0 .83
*
Replace any wrong sized orifices.
0 .83
0 .62
*
Replace the damaged gas line .
*
Replace the gas pressure regulator .