Wiring
3.3.3
Wire the power supply to the MVD Direct Connect I.S.
barrier
Procedure
Connect the power supply wires from the barrier, matching positive and negative (+
and –).
Figure 3-8:
A. I.S. terminals for connection to enhanced core processor
B. Non I.S. terminals for connection to remote host and power supply
3.3.4
Wire the remote host to the MVD Direct Connect I.S.
Barrier
1.
18
You can connect multiple MVD Direct Connect installations to a single power
supply, as long as each installation receives sufficient power.
For power supply to I.S. barrier connections, the power supply can be used to power
other equipment.
Barrier terminals
Connect the RS-485 wire from the barrier to the RS-485 terminals at the remote
host.
Micro Motion Liquified Natural Gas Meter