Procedure:
– Use hand-held multimeter - V.A.G. 1526 C- to measure volt‐
age between battery clamps -2- and -3-.
– Use results of test to determine following measures:
State of charge
(SOC):
"≥ 12.5 V"
"SOC < 12.5 V und
SOC ≥ 11.6 V"
"< 11.6 V"
– Record charge level in maintenance table.
Install in reverse sequence.
3.10
Mirror hanger indicating defective bat‐
tery: renewing battery on affected vehi‐
cles
Only for vehicles with mirror hanger for "Battery defective".
Procedure:
– Wait until shortly before vehicle delivery, then renew battery
according to instructions in workshop manual ⇒ Rep. gr. 27 ;
Battery; Removing and installing battery .
3.11

Brake fluid: changing

WARNING
Risk of accident if the brake pedal has too much free play.
♦ Make sure that the brakes work properly before the vehicle
is driven on the road.
WARNING
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
Risk of injury due to caustic brake fluid.
♦ Avoid contact with skin.
Measure:
No further measures necessary.
Charge battery ⇒ Rep. gr. 27 ; Battery; Charging battery .
Charge battery ⇒ Rep. gr. 27 ; Battery; Charging battery , and attach mirror hanger
for "Battery defective".