Noise Level; Torque Specifications; Dimensions; Power Cabinet - ABB Terra HP Generation 3 Installation Manual

Ul 175 kw static dc system
Hide thumbs Also See for Terra HP Generation 3:
Table of Contents

Advertisement

Technical data
12.13

Noise level

Noise level
Charge post, 500 A continuous up to
35 °C
Maximum noise level of the charge post

Power cabinet

12.14

Torque specifications

Parameter
Power cabinet, fasteners to the founda-
tion
Power cabinet, nuts on the PE busbars
Power cabinet, nuts on the AC power
busbars
Power cabinet, screws in the terminal
blocks
Power cabinet, nuts on the DC power
busbars
Charge post, fasteners to the founda-
tion
Charge post, fasteners on the PE busbar Between 33 and 44 Between 292 and
Charge post, screws in the terminal
blocks
DC input cable to the connector
M5 fasteners (if not specified)
M6 fasteners (if not specified)
M8 fasteners (if not specified)
M10 fasteners (if not specified)
M12 fasteners (if not specified)
M16 fasteners (if not specified)
12.15

Dimensions

12.15.1
Power cabinet
Parameter
Width (X-dimension)
Depth (Y-dimension)
74
Specification [dB(A)]
≤ 60 at 1 m (39.4 in)
68 at 1 m (39.4 in)
≤ 65 at 1 m (39.4 in)
Specification
[Nm]
[lb·in]
80
708
30
266
30
266
1.3
11.5
30
266
80
708
389
1.3
11.5
30
265.5
3.5
31.0
9
79.7
20
177
40
354
70
619.5
180
1593
Specification
[mm]
[in]
1170
46.1
770
30.3
9AKK107992A3069-EN | 004

Advertisement

Table of Contents
loading

This manual is also suitable for:

Terra hp generation 3 ulTerra hp 3

Table of Contents