SAVE THESE INSTRUCTIONS
The Direct Vent Freestanding Gas Stove must
be installed in accordance with these instructions.
Carefully read all the instructions in this manual first.
Consult the building authority having jurisdiction
to determine the need for a permit prior to starting
the installation.
Note: Failure to follow the instructions could
cause a malfunction of the heater which
could result in death, serious bodily in-
jury, and/or property damage. Failure to
follow these instructions may also void
your fire insurance and/or warranty.
Note: These instructions take precedence over
Simpson Dura-Vent instructions.

Specifications

Fuels:
H27U-NG is approved for use with natural
gas.
H27U-LP is approved for use with lique-
fied petroleum gases (propane).
Electrical: 120V A.C. system.
Optional Circulation Fan:
Variable speed, 125CFM High/75CFM Low.
Log Sets: Ceramic fibre, 4 per set.
Vent System: Coaxial (6-5/8" outer / 4" inner liner)
rigid flue and termination cap.
Information for Mobile /
Manufactured Homes After
First Sale
This Hampton
product has been tested and listed
®
by Intertek Testing Services as a Direct Vent Heater
to the following standard: ANSI Z21.88.
This Direct Vent System Appliance must be installed
in accordance with the manufacturer's installation
instructions and the Manufactured Home Construc-
tion and Safety Standard, Title 24 CFR, Part 3280,
or the current Standard of Fire Safety Criteria
for Manufactured Home Installations, Sites, and
Communities ANSI/NFPA 501A, and with CAN/
CSA Z240-MH Mobile Home Standard in Canada.
Hampton
®
H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove
This appliance installation must comply with the
manufacturer's installation instructions and local
codes, if any. In the absence of local codes follow
the current National Fuel Gas Code, ANSI Z223.1
and the current National Electrical Code ANSI/NFPA
70 in the U.S.A., and the current CAN/CGA B149
Gas Installation Code and the current Canadian
Electrical Code CSA C22.1 in Canada.
This Hampton
Mobile/Manufactured
®
Home Listed appliance comes factory
equipped with a means to secure the unit.
This Hampton
Mobile/Manufactured
®
Home listed appliance comes equipped
with a dedicated #8 ground lug to which
an 18 gauge copper wire from the steel
chassis ground must be attached.
This appliance may only be installed
in an aftermarket permanently located,
manufactured (USA only) or mobile
home, where not prohibited by local
codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases, unless a certified kit
is used.
installation
1) Provide adequate clearances for servicing,
proper operation and around the air openings
into the combustion chamber.
2) The appliance must be installed on a flat, solid,
continuous surface (e.g. wood, metal, concrete).
This may be the floor, or it can be raised up
on a platform to enhance its visual impact. The
appliance may be installed on carpeting, tile,
wood flooring or other combustible material,
because the appliance's base extends the full
width and depth of the appliance. The Direct
Vent Freestanding Gas Stove can be installed
in a wide variety of ways and will fit nearly any
room layout. It may be installed in a recessed
position, framed out into the room, or across
a corner.
3) The Direct Vent Freestanding Gas Stove is
approved for alcove installations, which meet
the clearances listed on in the "Clearance to
Combustibles" section. This unit is approved
for manufactured home installations, see
the "Manufactured Mobile Home Additional
Requirements" section and "Venting Arrange-
ments" section for the required vent arrange-
ments. If installed into a manufactured home
the unit must be bolted down to the floor.
4) This appliance is Listed for bedroom instal-
lations when used with a Listed Millivolt Ther-
mostat. Some areas may have further require-
ments, check local codes before installation.
5) This appliance is Listed for Alcove installations,
maintain minimum Alcove clearances as follows,
minimum width of 34-3/4" (882mm), a maximum
depth of 36" (914mm), and minimum ceiling
height of 51" (1295mm) from floor to ceiling.
6) We recommend that you plan your installation on
paper using exact measurements for clearances
and floor protection before actually installing this
appliance. Have a qualified building inspector
review your plans before installation.
11