IMPORTANT MESSAGE

SAVE THESE
INSTRUCTIONS
The Direct Vent Freestanding Gas Stove must
be installed in accordance with these instruc-
tions. Carefully read all the instructions in this
manual fi rst. Consult the building authority
having jurisdiction to determine the need for a
permit prior to starting the installation.
Note: Failure to follow the instructions
could cause a malfunction of the
heater which could result in death,
serious bodily injury, and/or prop-
erty damage. Failure to follow these
instructions may also void your fi re
insurance and/or warranty.
Note: These instructions take precedence
over Simpson Dura-Vent instruc-
tions.
SPECIFICATIONS
Fuels:
H27-NG is approved for use with
natural gas.
H27-LP is approved for use with lique-
fi ed petroleum gases (propane).
Electrical: 120V A.C. system.
Optional Circulation Fan:
Variable speed, 125/75.
Log Sets: Ceramic fi bre, 4 per set.
Vent System: Coaxial (6-5/8" outer / 4" inner
liner) rigid fl ue and termination cap.
INFORMATION FOR
MOBILE /
MANUFACTURED
HOMES
AFTER FIRST SALE
®
This Hampton
product has been tested and
listed by ITS Testing Services as a Direct Vent
Wall Furnace to the following standards:
CGA-2.17-M91, and ANSI Z21.88a-2007/CSA
2.33a-2007.
This Direct Vent System Appliance must be
installed in accordance with the manufacturer's
installation instructions and the Manufactured
Home Construction and Safety Standard, Title
24 CFR, Part 3280, or the current Standard of
Fire Safety Criteria for Manufactured Home
Installations, Sites, and Communities ANSI/
NFPA 501A, and with CAN/CSA Z240-MH
Mobile Home Standard in Canada.
®
Hampton
H27 Direct Vent Freestanding Gas Stove
This appliance installation must comply with the
manufacturer's installation instructions and local
codes, if any. In the absence of local codes fol-
low the current National Fuel Gas Code, ANSI
Z223.1 and the current National Electrical Code
ANSI/NFPA 70 in the U.S.A., and the current
CAN/CGA B149 Gas Installation Code and the
current Canadian Electrical Code CSA C22.1
in Canada.
®
This Hampton
Mobile/Manufactured
Home Listed appliance comes factory
equipped with a means to secure the
unit.
®
This Hampton
Mobile/Manufactured
Home listed appliance comes equipped
with a dedicated #8 ground lug to which
an 18 gauge copper wire from the steel
chassis ground must be attached.
This appliance may only be installed in
an aftermarket permanently located,
manufactured (USA only) or mobile
home, where not prohibited by local
codes.
This appliance is only for use with
the type of gas indicated on the rating
plate. This appliance is not convert-
ible for use with other gases, unless
a certifi ed kit is used.
BEFORE YOU START
Safe installation and operation of this appli-
ance requires common sense, however, we
are required by the Canadian Safety Standards
and ANSI Standards to make you aware of the
following:
INSTALLATION AND REPAIRS
SHOULD BE DONE BY A QUALI-
FIED SERVICE PERSON. THIS AP-
PLIANCE SHOULD BE INSTALLED,
REPAIRED, INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BY
A QUALIFIED SERVICE PERSON.
MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING, ETC. IT IS
IMPERATIVE THAT THE CONTROL
COMPARTMENT, BURNERS AND
CIRCULATING AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT
CLEAN
.

INSTALLATION

DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.
WARNING: FAILURE TO INSTALL
THIS APPLIANCE CORRECTLY WILL
VOID YOUR WARRANTY AND MAY
CAUSE A SERIOUS HOUSE FIRE.
CHILDREN AND ADULTS SHOULD
BE ALERTED TO THE HAZARDS OF
HIGH SURFACE TEMPERATURES,
ESPECIALLY THE FIREPLACE
GLASS, AND SHOULD STAY AWAY
TO AVOID BURNS OR CLOTHING
IGNITION.
YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
CLOTHING OR OTHER FLAMMA-
BLE MATERIAL SHOULD NOT BE
PLACED ON OR NEAR THE
APPLIANCE.
1) Provide adequate clearances for servicing,
proper operation and around the air openings
into the combustion chamber.
2) The appliance must be installed on a fl at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or it can be
raised up on a platform to enhance its visual
impact. The appliance may be installed on
carpeting, tile, wood fl ooring or other com-
bustible material, because the appliance's
base extends the full width and depth of the
appliance. The Direct Vent Freestanding
Gas Stove can be installed in a wide variety
of ways and will fi t nearly any room layout.
It may be installed in a recessed position,
framed out into the room, or across a corner.
3) The Direct Vent Freestanding Gas Stove
is approved for alcove installations, which
meet the clearances listed on in the "Clear-
ance to Combustibles" section. This unit
is approved for manufactured home in-
stallations, see the "Manufactured Mobile
Home Additional Requirements" section
and "Venting Arrangements" section for
the required vent arrangements. If installed
into a manufactured home the unit must be
bolted down to the fl oor.
4) This appliance is Listed for bedroom instal-
lations when used with a Listed Millivolt