10) Slide the thermodisc into the bracket on the left side of the rear firebox.
Connect the black wire 811 (90 degrees) & red (straight, from speed
controller) wires to the thermodisc.
Thermodisc
Braket
11) Mount the blower assembly in position under the base of the stove
and secure with the 2 supplied bolts (2-1/4" #20 hex head).
12) Before re-attaching the rear access panel, connect live wire (black/
from fan) to black wire 704 (from speed controller). Use the clip wire
holders to organize the wires.
Clip Wire
Holders
This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
14
Thermodisc
Tighten the 2 bolts
Live Wire Black
(from fan) & Black
Wire 704 (labeled)
WARNING: Electrical Grounding Instructions
13) Slide the Rear Access Panel back into position. Make sure the wires
are not blocking the passage of the relief door. Secure with 2 screws.
Grounding lug in fan:
Ground wire to fan
Ground from power cord
Grounding lug in unit:
Split/Lock washer
(120V AC)
Neutral
Ground /Green
Live
ON
Black
Rotary Speed
Control
Hampton
®
H27U-NG/H27U-LP Direct Vent Freestanding Gas Stove
Relief
Door
Nut
Split/Lock washer
Ground wire to unit
Star washer
Nut
Nut
Ground wire from fan
Star washer
Green
Fan
Fan
Ground
White
Black
OFF
Red
Black
Fan Thermodisc
(normally open)