TMPL

Temperature limit inquiry
Format
GET□TMPL
<n>
Number
<v>
Temperature value 0.0 to 127.9 °C
Environment
Power
OFF
ON
X
O
Response
Private commands (disclosed upon request)
Temperature limit is returned as '
For details on other responses, refer to the "Error List".
Description
(1)
This returns the limit value (of machine-stoppage) of each temperature sensors.
(2)
Number of temperature sensors varies according to model.
(3)
When returning multiple temperature sensor values, values will be separated with a comma.
There are cases when a number of sensors is 0. In this case, there will not be a comma.
(4)
For correspondence of temperature sensor sequence and actual installation location, inquire
separately.
Example
Setting
None
Reference
> GET TMPL
< g:TMPL=5,71.0,90.0,57.0,44.0,53.0
* Commands are indicated by ">", and responses are indicated by "<".
Revision History / Date
0 to 255
PM
D-RGB A-RGB1 A-RGB2 COMP
X
Changes
Projector WUX10 MarkII User Commands
Input
VIDEO
HDMI
-
'
g:TMPL=<n>{,<v>}
This retrieves the temperature sensor limit values.