Name
LCD Display
Bi-direction
open
Y1 FUNC
F7.10
collector
SELE
output
terminal Y1
Bi-direction
open
Y2 FUNC
F7.11
collector
SELE
output
terminal Y2
Function
RELAY
F7.12
selection of
OUTPUT
output relay
F7.13
FAR duration
FAR RANGE
F7.14
FDT1 level
FDT1 LEVEL
F7.15
FDT1 lag
FDT1 LAG
F7.16
FDT2 level
FDT2 LEVEL
F7.17
FDT2 lag
FDT2 LAG
F7.18
~
Reserved
RESERVED
F7.25
Functions of
ANALOG
F7.26
terminal AO1
OUTPUT1
Functions of
ANALOG
F7.27
terminal AO2
OUTPUT2
Functions of
terminal DO(no
DIGITAL
F7.28
output when
OUPUT
F7.07=44~46)
ANALOG
Analog output
F7.29
OUTPUT
range
OFFSET
AO1 output
F7.30
A01 CALIB
gain
AO2 output
F7.31
A02 CALIB
gain
Maximum
MAX
output
F7.32
OUTPUT
frequency of
PULSE
DO
Preset counting
SET COUNT
F7.33
value reaches
VALUE
reference value
Specified
SPECIFIED
F7.34
counting value
COUNT
Group 7: Terminal Function Parameters
0:Running signal(RUN)
1:frequency arriving signal(FAR)
2:frequency detection threshold (FDT1)
3:frequency detection threshold (FDT2)
4:overload signal(OL)
5:low voltage signal(LU)
6:external fault signal(EXT)
7:frequency high limit(FHL)
8:frequency low limit(FLL)
9:zero-speed running
10:Completion of simple PLC operation
11:PLC cycle completion indication
12:preset counting value arriving
13:specified counting value arriving
14:reference length arriving indication
15:drive ready (RDY)
16:drive fault
17:extended functions of host
18:Upper and lower limits of traverse operating frequency
19: preset operating time out
0.00~650.0Hz
0.00~650.0Hz
0.00~650.0Hz
0.00~650.0Hz
0.00~650.0Hz
-
0: Output frequency before slip compensation (0~Max output frequency)
1:Output frequency after slip compensation (0~Max output frequency)
2:Preset frequency (0~Max output frequency)
3:Output current (0~2 times of drive's rated current)
4:Output current (0~2 times of motor's rated current)
5:Output torque (0~2 times of motor's rated torque)
6:Output voltage (0~1.2 times of drive's rated voltage)
7:Bus voltage (0~800V)
8:VCI (0~10V)
9:CCI (0~10V/0~20mA)
10:Output power (0~2 times of rated power)
11:Extended function of host 2(0~65535)
Unit's place of LED: AO1 offset selection
0: 0~10V or 0~20Ma
Ten's place of LED: AO2 offset selection
0:0~10V or 0~20mA
0.0~200.0%
0.0~200.0%
0.1~50.0 (up to 50k)
F7.34~9999
0~F7.33
EV2000 Series Universal Variable Speed Drive User Manual
Setting Range
1: 2~10V or 4~20mA
1: 2~10V or 4~20mA
Appendix 1 Parameters
Factory
Unit
Modif
setting
1
0
1
1
1
16
0.01Hz
2.50Hz
0.01Hz
50.00Hz
0.01Hz
1.00Hz
0.01Hz
25.00Hz
0.01Hz
1.00Hz
-
0
1
0
1
3
1
0
1
00
0.1%
100.0%
0.1%
100.0%
0.1
10.0k
1
0
1
0
99
×
×
×
*