Para.
Name
Parameter displayed at
F8.03
STOP state
Coefficient of displayed
F8.04
speed
Coefficient of displayed line
F8.05
speed
Coefficient of displayed
F8.06
analog close loop
parameter/ feedback
Group F8: Display Parameters
LCD Display
Binary settings:
0:No display;
Unit's place of LED:
Bit0: Reference frequency(Hz)
Bit1: External counting value(no unit)
Bit2: Spinning speed(R/MIN)
Bit3: Reference speed(R/MIN)
STOP DISPLAY
Ten's place of LED:
Bit0: Line speed(M/S)
(flashes, ▲ and
Bit1: Reference line speed(M/S)
▼ key are valid
Bit2: VCI(V)
in frequency
Bit3: CCI(V)
displaying status;
Hundred's place of LED:
the status will be
Bit0: Analog close loop feedback(%)
saved at power
Bit1:Analog close loop setup(%)
off)
Bit2: Actual length
Bit3: Reference length
Thousand's place of LED:
Bit0: Terminal status(no unit)
Bit1: Bus voltage
Note: The reference frequency will be displayed in
default if all the Bits are 0
0.1~999.9%
Spinning speed = actual spinning speed*F8.04(PG)
Spinning speed=
120*operating Frequency/FH.00*F8.04(non PG)
SPEED
Reference speed =
FACTOR
close loop reference speed*F8.04(PG)
Reference speed=
120*reference frequency/FH.00*F8.04(non PG))
Note: No influence to actual speed
0.1~999.9%
Line speed = running frequency*F8.05(non PG))
Line speed = spinning speed*F8.05(PG)
LINE SPEED
Reference line speed = reference frequency*F8.05(non
FACTOR
PG))
Reference line speed=reference speed*F8.05(PG)
Note: No influence to actual speed
CLOSELOOP
0.1~999.9%
DISPLAY
Note: Analog close loop reference/feedback displaying
FACTOR
range:0~999.9
EV2000 Series Universal Variable Speed Drive User Manual
Setting Range
1:Display
Appendix 1 Parameters
Factory
Unit
Setting
1
1FF
0.1%
100.0%
0.1%
1.0%
0.1%
100.0%
101
Modif.
○
○
○
○