Emerson EV2000 Series User Manual page 65

Universal variable speed drive
Table of Contents

Advertisement

Setting
5
Acc/Dec time 2
6
External fault signal normally-open input
7
External fault signal normally-close input
8
RESET signal
9
Forward jog operation
10
External terminals for reverse jog operation
11
Coast-to-stop(FRS)
12
Frequency ramp up (UP)
13
Frequency ramp down(DN)
14
Pause the PLC operation
15
Acc/Dec prohiBit
16
3-wire operation control
External interrupt signal normally-open
17
input
External interrupt signal normally-close
18
input
19
DC injection braking command (DB)
20
Close-loop disabled
21
PLC disabled
22
Frequency selector 1
23
Frequency selector 2
24
Frequency selector 3
Frequency reference is input via terminal
25
CCI forcibly
26
Reserved
27
Terminal control mode is forcibly enabled
28
Control mode selector 1
29
Control mode selector 2
30
Preset close-loop reference 1
31
Preset close-loop reference 2
32
Preset close-loop reference 3
33
Start traverse operation
34
Reset the traverse operating status
35
External stop command
36
Reserved
37
Drive operation prohiBiting
38
Reserved
39
Length clearing
40
Auxiliary reference frequency clearing
41
Reset PLC stopping status
42
Counter's zero-clearing signal input
43
Counter's trig signal input
44
Input the signal of length
45
Pulse input
46
Single-phase speed measuring input
Speed measuring input SM1(only set for
47
X7)
48
Speed measuring input SM2(only for X8)
Introductions to functions listed in Table 5-5:
Functions
EV2000 Series Universal Variable Speed Drive User Manual
Chapter 5 Parameter Introductions
1~3: setting speed reference
Up to 8 speed references can be set through different
ON/OFF combinations of terminals K
Table 5-6 On/Off combinations of terminals
K
K
K
3
2
1
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
The frequency references will be used in MS speed
operation and simple PLC operation. Take MS speed
operation for example:
Definitions of terminals X1, X2 and X3:
After setting F7.00 to 1, F7.01 to 2 and F7.03 to 3,
terminals X1, X2 and X3 can be used in MS speed
operation, as shown in Fig. 5-39.
Output freq.
speed2
Common
operating
speed1
freq.
Speed
command
K
1
K
2
K
3
Fig. 5-39 Multi-step speed operation
In Fig. 5-40, terminal control is selected. The operating
direction can be controlled by K
operating frequency and preset frequency 1~7 can be
selected through different On/Off combinations of K
and K
.
3
, K
and K
.
3
2
1
Frequency setting
Common operating
frequency
Preset frequency 1
Preset frequency 2
Preset frequency 3
Preset frequency 4
Preset frequency 5
Preset frequency 6
Preset frequency 7
speed7
speed6
speed5
speed4
speed3
and K
. Common
4
5
61
Time
, K
1
2