Appendix 1 Parameters
Para.
Name
F3.12
Motor tone adjustment
F3.13
Jog frequency
F3.14
Jog interval
F3.15
Acc time of Jog operation
F3.16
Dec time of Jog operation
F3.17
Acc time 2
F3.18
Dec time 2
F3.19
Acc time 3
F3.20
Dec time 3
F3.21
Acc time 4
F3.22
Dec time 4
F3.23
Preset frequency 1
F3.24
Preset frequency 2
F3.25
Preset frequency 3
F3.26
Preset frequency 4
F3.27
Preset frequency 5
F3.28
Preset frequency 6
F3.29
Preset frequency 7
F3.30
Skip frequency 1
F3.31
Range of skip frequency 1
F3.32
Skip frequency 2
F3.33
Range of skip frequency 2
F3.34
Skip frequency 3
F3.35
Range of skip frequency 3
Para
Name
LCD Display
PLC operation
PLC OPR
F4.00
mode
MODE
selection
STAGE 1
F4.01 Phase 1 setup
SET
Group F3: Auxiliary parameters
LCD Display
MOTOR TUNING
0~10
JOG OPR FREQ
0.10~50.00Hz
JOG INTERVAL TIME
0.0~100.0s
JOG ACC TIME
0.1~60.0s
JOG DEC TIME
ACC TIME2
DEC TIME2
0.1~3600
ACC TIME3
Note:
DEC TIME3
Default unit is second; unit of Acc/Dec time is decided by F9.09
ACC TIME4
DEC TIME4
MULTIBAND FREQ 1
MULTIBAND FREQ 2
MULTIBAND FREQ 3
MULTIBAND FREQ 4
F0.13 (Lower limit of frequency) ~F0.12(upper limit of frequency)
MULTIBAND FREQ 5
MULTIBAND FREQ 6
MULTIBAND FREQ 7
SKIP FREQ1
0.00~650.0Hz
SKIP FREQ BAND1
0.00~30.00Hz
SKIP FREQ2
0.00~650.0Hz
SKIP FREQ BAND2
0.00~30.00Hz
SKIP FREQ3
0.00~650.0Hz
SKIP FREQ BAND3
0.00~30.00Hz
Group F4: Operating Parameters
Unit's place of LED: PLC operation mode
0:disabled
2: Holding at the final value after single cycle of operation
3:Operate continuously
Ten's place of LED: Restarting mode after stopping
0:Run again from phase 1
1:Continue to run from the stopping phase
2:Operate at the time and frequency when the drive stops or fault occurs
Hundred's place of LED: Save at power off
0:Not saving
1:Save the time and frequency at power off
Thousand's place of LED: selecting the unit of time
0:second
Unit's place of LED: Frequency setting
0:Pre-set frequency 1(F3.23)
2:Close loop reference 1(F5.20)
Ten's place of LED: Running direction selection
0:Run forward
2:Decided by operating instructions
Hundred's place of LED:Acc/Dec time selection
0:Acc/Dec time 1
2:Acc/Dec time 3
EV2000 Series Universal Variable Speed Drive User Manual
Setting range
Setting range
1:Stop after operating for 1 cycle
1:Minute
1:Decided by F0.00 parameter
3:Decided by F5.01 parameter
1:Run reverse
1:Acc/Dec time 2
3:Acc/Dec time 4
Factory
Unit
Modif.
setting
1
0
0.01Hz
5.00Hz
0.1s
0.0s
0.1
5.5kW~
22kWG:
6.0s
30kW~
0.1
280kWP:
20.0s
5.00Hz
10.00Hz
20.00Hz
0.01Hz
30.00Hz
40.00Hz
45.00Hz
50.00Hz
0.01Hz
0.00Hz
×
0.01Hz
0.00Hz
×
0.01Hz
0.00Hz
×
0.01Hz
0.00Hz
×
0.01Hz
0.00Hz
×
0.01Hz
0.00Hz
×
Factory
Unit
Modif.
setting
1
0000
×
1
000