0F51: Waste Toner Full Sensor Trouble; 13C0: Printer Control Board Malfunction; 13Dd: Backup Data Error - Konica Minolta MagiColor 1600W Service Manual

Field service manual
Hide thumbs Also See for MagiColor 1600W:
Table of Contents

Advertisement

Field Service Ver. 1.0 Nov. 2008
17.2.11

0F51: Waste toner full sensor trouble

Waste toner full sensor (PS7)
Step
Check the PRCB connector for proper con-
1
nection and correct as necessary.
2
PS7 sensor check.
3
Change PRCB.
17.2.12

13C0: Printer control board malfunction

Printer control board (PRCB)
Step
Check the PRCB connector for proper con-
1
nection and correct as necessary.
2
Change PRCB.
17.2.13

13DD: Backup data error

Printer control board (PRCB)
Step
Confirm mounting status of EEPROM on
1
the printer control board, and make modifi-
cation if necessary.
2
Change PRCB.
Relevant electrical parts
Action
Relevant electrical parts
Action
Relevant electrical parts
Action
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
WIRING DIAGRAM
Control signal
WIRING DIAGRAM
Control signal
17. Malfunction code
Location (Electrical
component)
Location (Electrical
component)
Location (Electrical
component)