Set Default; Calibration; User Service Tab; Top Adjustment - Konica Minolta MagiColor 1600W Service Manual

Field service manual
Hide thumbs Also See for MagiColor 1600W:
Table of Contents

Advertisement

9. Remote panel utility (Only for magicolor 1600W)
9.2.2

Set Default

Display
Apply
9.2.3

Calibration

Display
Start
9.3

User Service tab

9.3.1

Top Adjustment

Function
• Adjusts the top margin of media for single-sided printing.
Use
• To correct a misaligned print image.
Plain Paper:
Thick Paper:
Envelope:
Setting
/procedure
54
• Toner Low Message:
Specifies whether a printer indicator blinks or a warning message
appears in the status display box of the Remote Panel Utility when
toner is about to run out. If Off is selected, neither of these notifications
appear when the toner is about to run out.
The default setting is On.
• Toner Out Stop:
Specifies whether to stop or continue printing when a toner empty con-
dition is detected.
The default setting is On.
• Energy Save Time:
Specifies the length of time before the machine enters energy saver
mode after the last print is received or the last key operated.
The default setting is 30 (min).
• Auto Continue:
If Off is selected, the next print job will not be performed if a paper size
error occurred in the printer, unless the Clear key is pressed to cancel
the error.
If On is selected, the next print job is sent if a paper size error occurred
in the printer, the error is automatically cancelled, and the next print job
is performed.
The default setting is Off.
Performs the calibration operation.
Adjust the head margin of plain paper.
Adjust the head margin of thick paper.
Adjust the head margin of envelope.
-15 to +15 (1 step: 0.2 mm)
Field Service Ver. 1.0 Nov. 2008