Field Service Ver. 1.0 Nov. 2008
6.3.9
Transfer roller unit
1. Remove the imaging cartridge.
See P.13
[1]
3. To reinstall, reverse the order of removal.
NOTE
• When the transfer roller unit is replaced with a new one, it is necessary to reset the
maintenance counter.
For magicolor 1600W: See P.59
For magicolor 1650EN: See P.87
• Make calibration after replacing the transfer roller unit.
For magicolor 1600W: See P.54
For magicolor 1650EN: See P.70
[2]
A034F2C021DA
2. Press and pull the levers [1] at both
sides forward to remove the transfer
roller unit [2].
NOTE
• Use care not to lose the two springs
of the transfer roller unit. They can
easily come off.
6. Other
29