Table 5-1 Alarm Indications On 24Dti - NEC Neax 2000 IVS2 Manual

Integrated voice server
Hide thumbs Also See for Neax 2000 IVS2:
Table of Contents

Advertisement

LED INDICATION
LED
NORMAL
RUN
Flash
(120 IPM)
CRC
Off
PCM
Off
FRM
Off
RMT
Off
AIS
Off
2
NEAX2000 IVS
ISDN System Manual
ND-70919 (E), Issue 1.0

Table 5-1 Alarm Indications on 24DTI

FAULT
CAUSE
On or Off
Abnormal
operation of DTI
card
On
Bit Error Rate
exceeds the
predetermined
value
On
No PCM signals
arrive from the
distant office
On
Frame Alignment
signals from the
distant office can-
not be received
On
Frame Alignment
signals cannot be
sent to the
remote PBX
On
Remote PBX is in
the loop-back test
CHAPTER 5 OPERATION TEST
Interoffice Transmission Line Test
FAULT
ACTION
Confirm the programming data:
1
CM05, CM07 YY=01.
Check to see if the SENS
2
switch is set as per the AP
number (04-15, 20-31)
assigned by CM05.
Reset the MB switch
3
(Down→Up→Down)
If the fault cannot be cleared,
4
replace the card.
Check the receive line and
1
external equipment.
Replace the remote DTI card.
2
Check to see if the DTI cable is
1
correctly connected.
Plug and unplug the DTI card.
2
Repeat this two or three times.
Check the receive line and
1
external equipment.
Replace the remote DTI card.
2
Check the transmission line
1
and external equipment.
Replace the DTI card.
2
Check the switch settings of
1
the remote DTI card.
Page 191