SP R AY B A R
REMOVAL
Carefully pull the spray bar from the water supply hose.
INSTALLATION
The spray bar, located in the water trough, supplies
water to the individual ice cube cups. To be correctly
installed, the spray bar must–
• Be positioned with the clean-out caps on the right.
• Sit fully seated and horizontally level.
INCORRECT.
Spray bar positioned with clean-out caps on the left.
INCORRECT.
Spray bar is not fully seated or level.
CORRECT.
Spray bar is fully seated, level, and positioned with the clean-
out caps on the right..
TEC_TM_155 REV. A
M A I N T E N A N C E , C A R E & C L E A N I N G
12/07/2021
P UMP CL E A N - OU T C A P
REMOVAL
1. Remove the pump clamp. See fig. 1.
2. Pull the clean-out cap down.
INSTALLATION
1. Slide the clean-out cap over the hole beneath
the pump.
2. Reinstall the pump cap clamp.
FIG. 1.
Pump cap and clamp locations.
15" T RUE I CE
M AC HINE IN STA L L GUID E
®
Pump cap
Clamp