G ENER AL M AINTENANCE
You are responsible for maintaining the ice machine
in accordance with the instructions in this manual.
Maintenance procedures are not covered by warranty.
True recommends performing the following
maintenance procedures a minimum of once every six
months to ensure reliable, trouble-free operation.
WA R NING: IF YOU D O NO T UND ER S TA ND
T HE NECE S S A RY P R O CEDUR E S O R S A F E T Y
P R EC AU T ION S, C A L L YOUR L O C A L T RUE
SER V ICE R EP R E SEN TAT I V E T O P ER F O R M
M A IN T EN A NCE P R O CEDUR E S F O R YOU.
C AU T ION: TA K E C A R E DUR ING OP ER AT ION,
M A IN T EN A NCE , O R R EPA IR S T O AV OID CU T S
O R P INCHING F R OM A N Y C A BINE T PA R T/
C OMP ONEN T
MAINTENANCE
CLEAN CABINET
EXTERIOR
SANITIZE ICE
MACHINE
DESCALE ICE
MACHINE
CLEAN
CONDENSER COIL
CHANGE THE
WATER FILTER
CHECK ICE
QUALITY
Page 44 of 64
T RUE RE S ID E N TI A L
M A I N T E N A N C E , C A R E & C L E A N I N G
WEEKLY
SEMI-ANNUAL
X
X
X
X
X
X
X
®
E X T ER IO R CL E A NING
Clean the exterior as needed. Follow stainless steel
cleaning recommendations (page 47) to ensure your
machine always looks like new.
D E S C A L ING & S A NI T I Z ING
Descale and sanitize every 6 months. See "Descaling &
Sanitizing" (page 49).
WAT ER F ILT ER R EP L A CEMEN T
Replace the water filter at least once every 12 months.
More frequent replacement may be required based
on your water quality. See "Water Filter Replacement"
(page 45).
C OND EN SER CL E A NING
For optimum operation, clean your condenser coil
every 6 months. See "Condenser Coil Cleaning"
(page 46).
ANNUAL
X
X
X
X
X
12/07/2021
AFTER
PROLONGED
AT START-UP
SHUTDOWN
X
X
X
X
X
X
TEC_TM_155 REV. A
X
X
X
X

Hide quick links: