DE SC ALING & SANITIZING
You should fully descale your ice machine every 6
months. Descaling also involves removing key ice
machine parts and rinsing them and the inside of the
machine with ice machine descaler.
Sanitizing the ice machine removes potential biological
contaminations and molding. The sanitation process
is identical to the descaling process, except that a
sanitizing agent is used in place of the descaling
chemicals.
WA R NING: W E A R RUBBER G L O V E S A ND E Y E
P R O T EC T ION W HEN H A ND L ING ICE M A CHINE
D E SC A L ER O R S A NI T I Z ER .
C AU T ION: D O NO T C OMBINE D E S C A L ER A ND
S A NI T I Z ER .
D E S C A L ING
CLEAN
1. Press and hold
will show dES.
LIGHT
2. Press
and / or
either
dES
(descale only) or
and sanitize).
Run descale
cycle only
3. With the display showing the desired cycle, press
the TRUE logo. The display will show Str.
LIGHT
4. Press
and / or
Str
Stb
either
or
(standby). This determines the ice
machine's action upon completion of the selected
cleaning cycle.
Machine will begin
ice making sequence
TEC_TM_155 REV. A
M A I N T E N A N C E , C A R E & C L E A N I N G
for 3 seconds. The display
CLEAN
until the display shows
bth
(both descale
Run both descale
and sanitize cycles
CLEAN
until the display shows
Machine will
enter standby
5. With the display showing the desired action, press
the TRUE logo. The selected cleaning cycle will
begin.
6. The display will alternate between
(preclean) for approximately 3 minutes.
7. When the display shows Add, pour 6 fl. oz. of
undiluted True Ice
spray compartment behind the water shutters.
8. After adding the descaler, press the TRUE logo.
The automatic cycle will continue.
While running the
automatic clean cycle
9. Wait for the rinse and drain cycles to complete
(30 minutes). For light descaling, proceed to
step 14.
10. Remove the ice guide, water shutters, spray
bar and pump clean-out cap. See "Interior
Components" (page 51).
11. Mix a descaling solution of 10 fl. oz. undiluted
True Ice
Machine Descaler and 1 gal. of water.
TM
12. With approximately half the descaling solution,
clean the removed parts with a brush; then soak
them for 20 minutes.
13. With the remaining solution, descale the ice
bin, door, door gasket, spray compartment, and
evaporator.
14. Rinse all parts with clean water.
15" T RUE I CE
12/07/2021
PrE
Preclean stage
Machine Descaler into the
TM
Add cleaning
chemicals
M AC HINE IN STA L L GUID E
®