EL EC T R IC A L OU T L E T L O C AT ION
To minimize the depth of the cutout opening, the
electrical outlet must be positioned as shown below.
Outlet must be flush with wall.
C o u n t e r t o p
D O N O T I N S T A L L
O U T L E T I N T H I S A R E A !
R e a r w a l l o f c u t o u t
1 5 " ( 3 8 1 m m )
o p e n i n g
TEC_TM_155 REV. A
P R I O R T O I N S T A L L A T I O N
DR AIN CONNEC TION
The True Ice
WA R NING: P R OP ER IN S TA L L AT ION R EQUIR E S
C ONNEC T ION T O T HE WAT ER SUP P LY A ND
A D R A IN. T HE SE C ONNEC T ION S A R E T HE
R E SP ON SIBIL I T IE S O F T HE IN S TA L L ER . TRUE
WI LL NOT WARRANT LEAKS O R DAMAG E
CAUSED BY IMPROPER INSTALLATION .
IMP R OP ER C ONNEC T ION S C A N R E SULT IN
P ER SON A L IN JURY, P R OP ER T Y D A M A G E A ND
IMP R OP ER OP ER AT ION. T HE ICE M A CHINE
MU S T BE IN S TA L L ED A C C O R DING T O A L L
A P P L IC A BL E N AT ION A L , S TAT E A ND L O C A L
C O D E S A ND R EGUL AT ION S.
DO NOT
3/8" I.D.
• 48" (1,219.2 mm) Clear PVC drain hose, 1/2"
male NPT connector, and 1/2" hose clamp
provided by True
• Using hose larger than 1/2" I.D. may require a
larger pump. A check valve may be required to
prevent excessive cycling of the drain pump.
• Be sure to use the correct I.D. hose for your vertical
rise to ensure the proper flowrate and prevent drain
time alarms. For more information, see "Drain Time
Alarm" (page 38).
• If the installation requires a
than 84" (2,133.6 mm)
pump to cover the additional required pumping
height. Connect the drain tube outlet from the ice
maker to the external drain pump inlet.
remove the internal drain pump provided with the
ice
way will void the warranty.
DO NOT USE HOSE SMALLER THAN 3/8" I.D.
• The floor drain must be large enough to
accommodate additional drainage.
• The drain pump discharge line must terminate at an
open site drain.
• Be sure to thoroughly inspect all connections after
installation to ensure there are no leaks. Use of
thread sealant recommended.
12/07/2021
machine has a built-in drain pump.
®
reduce drain connections any smaller than
include an external drain
maker. Altering the internal components in any
15" T RUE I CE
M AC HINE IN STA L L GUID E
®
vertical rise greater
Do not