Display
Definition
Clean cycle reminder
Drain pump failure
Thermistor 1 Failure
Thermistor 2 Failure
Fill mode
Condenser coil cleaning reminder
Freeze time
Ice storage bin is full
Water level sensor
Ice level sensor
Harvesting ice
Harvest time
Making ice
High Pressure sensor
Low Pressure sensor
Water filter reminder
Evaporator temperature
Condenser temperature
TEC_TM_155 REV. A
C A B I N E T O P E R A T I O N
E L E C T R O N I C D I S P L A Y C O D E S
Detailed Description
In Menu Mode: view the number days elapsed since the
automatic clean cycle was performed
Clogged or kinked drain line. Drain was not able to clear
within 5 minutes of running.
Thermistor 1 is located on the evaporator outlet tube
and is used for terminating the harvest. E1 means the
probe has a bad or loose connection.
Thermistor 2 is located on the condenser outlet tube
and is used for fan cycling. E2 means the probe has a
bad or loose connection.
Water fills the reservoir for 2-3 minutes
In Menu Mode: view the number of days elapsed since
the last condenser coil cleaning.
In Menu Mode: view the most recent freeze times in
minutes. View history of five previous cycles:
-1 (most recent), -2, -3, -4, -5
Ice has reached the full level and the unit is in
In Menu Mode: h1 is the water level reading inside the
sump tank read in mm of H 2 O.
In Menu Mode: h2 is the ice level reading inside the ice
storage bin in cm.
Full = 35.0 and Empty = 55.0
Ice cubes drop in the storage bin and water fills the
reservoir for the next batch of ice.
In Menu Mode: view the most recent harvest times in
minutes. View history of five previous cycles
-1 (most recent), -2, -3, -4, -5
Circulation pump is running, machine sprays water into
the molds to make cubes.
In Menu Mode: P1 is the high side pressure transducer
taken at the compressor discharge read in PSI (lb/in
In Menu Mode: P2 is the low side pressure transducer
taken at the compressor suction read in PSI (lb/in
In Menu Mode: view the number of days elapsed since
the last water filter replacement
In Menu Mode: t1 is the evaporator outlet temperature
read in degrees Fahrenheit
In Menu Mode: t2 is the condenser outlet temperature
read in degrees Fahrenheit
12/07/2021
15" T RUE I CE
M AC HINE IN STA L L GUID E
®
standby.
2
)
2
)
Page 37 of 64