5

Setting-up the Applicator

14
5.1

Adjusting the Supporting Plate

The supporting plate (2) can be set vertically to adjust the position of the label on the tube and therefore to adjust the
measure E.
L
Tube length
F
Length of tread or cap
E
Distance label - upper edge labeling area
R
Distance label - liner edge
P
Distance paper guiding edge - chassis
N
Distance chassis - supporting plate
Supporting plate over chassis - N > 0
Supporting plate under chassis - N < 0
Figure 13
1
Figure 14
F
E
B
R
P=37
AXON 1.1
Measures for supporting plate positioning
2
3
Setting the supporting plate
L
N
The following correlation can be deduced from the
figure:
L + N = F + E + B + R + P
The measure for the positioning of the supporting plate
results in:
N = (F + B + R + P - L) + E
 Set the supporting plate (2) by turning the spindle
(1) to the measure N.
F
E
B
R
P=10
AXON 1.2