Cleaning The Drain Valve - PRONAR PT512 Operator's Manual

Table of Contents

Advertisement

CHAPTER 5
Scope of maintenance
Tilt out drain valve stem (1) placed in lower part of the tank (2) – the tank is
placed on brackets of right longitudinal of lower frame.
When the stem is released, valve should be automatically closed and air
removal from tank should be stopped.
Drain water from air reservoir:
5.3.5

CLEANING THE DRAIN VALVE

Scope of maintenance
Completely reduce the pressure in the air reservoir.
Unscrew the valve.
Clean valve and blow with compressed air.
Replace the copper seal with new one.
Screw in the valve, fill the air reservoir and check its tightness.
DANGER
Before dismantling the drain valve, release air from the tank.
The compressed air in the tank will cause the removal of water to the
exterior.
If valve stem does not return to its position, then the whole drain valve
must be unscrewed and cleaned, or replaced (if damaged) with new
one – see chapter 5.3.5.
• every 7 days of use.
Reduction of pressure in tank is achieved by tilting the drain valve
stem.
5.19