Ensure that two or more pairs of photocells do not have
the same address. If no BUS accessories are used, leave
terminals 1 and 2 free.
To allow operation of the installed BUS accessories,
store them on the board as described in paragraph 5.3.
The following table describes how to set the dip-switches located inside
the transmitter and receiver of the BUS photocells.
Addressing BUS photocell PAIRS
DIP-SWITCH
T X
ADDRESS
Dip 1 Dip 2 Dip 3 Dip 4
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON

4.2 Terminal board J2 (outputs)

OUT 1 - Output 1 open-collector GND (terminal 13): The output can
be set in one of the functions described in the ADVANCED programming
04
(par. 6). The default value is
- Beam OPEN or in
load: 24 VDC with 100 mA.
OUT 2 - Output 2 open-collector GND (terminal 15): The output can
be set in one of the functions described in the ADVANCED programming
03
(par. 6). The default value is
24 VDC with 100 mA.
OUT 3 - Output 3 open-collector GND (terminal 17): The output can
be set in one of the functions described in the ADVANCED programming
19
(par. 6). The default value is
24 VDC with 100 mA.
OUT 4 - Relay output 4 (terminals 19, 20, 21): The output can be set
in one of the functions described in ADVANCED programming (par.
01
6). The default value is
- BEAM ILLUMINATION. Maximum load:
24 VDC with 800 mA.
4.3 Terminal board J3 (external fl ashing lamp)
LAMP: to these terminals you can connect a 24VDC FAACLED external
flashing lamp. The integrated flashing traffic light must be connected
independently to connector J18.
The 24V FAACLIGHT with incandescent lamp cannot be
connected to the J3 connector

4.4 Terminal board J4 (loop detector)

LOOP 1: magnetic loop LOOP 1 (OPEN, terminals 24-25): for
OPENING.
LOOP 2: magnetic loop LOOP 2 (SAFETY/CLOSE, terminals 26-27):
for SAFETY/CLOSING.
B680H
DIP-SWITCH
SAME
R X
Pair
Type
no.
1° Pair
2° Pair
3° Pair
CLOSE
4° Pair
photocells
5° Pair
6° Pair
7° Pair
Single
OPEN
PULSE
PAUSE.
Maximum
- CLOSED BEAM. Maximum load:
- WARNING LAMP. Maximum load:

4.5 Connector J5 (Motor)

Rapid connector for connecting the motor.

4.6 Connector J17 (Encoder)

The B680H barrier is equipped with a device for detecting the opening
angle/bar position to ensure greater anti-crushing safety thanks to
the possibility of reversing the direction of movement the moment in
which an obstacle is detected. This device interfaces with the board
through connector J17.

4.7 Connector J10 (Radio)

Used for the rapid connection of the Minidec, Decoder and RP / RP2
Receivers (Fig. 28). If a 2-channel receiver is used, like the RP2, it will
be possible to directly command automated system OPEN and CLOSE
from a 2-channel radio control. If a 1-channel receiver is used, like the
RP, it will only be possible to command OPEN.
Boards should be inserted and removed ONLY after
having cut off electrical power

4.8 Connector J11 (Beam break-out sensor)

Designed for connecting the break-out sensor for the pivoting beam
(if present). The sensor is optional. If it is not present, do not remove
the installed jumper.

4.9 Connector J12 (Emergency battery)

This connector is for connecting a battery (optional) for ensuring
automated system operation in case of temporary cut off of the main
power supply.

4.10 Connector J13 (36VDC Power Supply)

This factory-wired connector powers the E680 board.
The terminal shown in Fig. 1 ref.
to the system earth by the installer during the electrical
connection operations.
J5
MOTOR
POWER
J13
4.11 Connector J18 (fl ashing traffi c light)
This connector is for connecting the flashing traffic light built into the
barrier head. The flashing traffic light visually signals barrier movement
and, if needed, regulate access to the property using traffic light signals.

4.12 Connector J16 (beam lights)

Connector which allows the rope light for the rod to be connected,
providing visual warning of barrier movement. The connector has a
common GND connection and two +36V (BLR / BRG) outputs. The
default value is 02 - "BEAM LIGHTING TYPE 2" for OUT 5, 04 - "BEAM
OPEN OR PAUSED" for OUT 6.
10
must be connected
RED or WHITE
BLACK