"EXPERT" CONFIGURATION
Display
Function
01
If this function is activated, automatic closing occurs after the pause time.
If this function is activated, two distinct input operation mode is obtained: OPEN for opening
02
and CLOSED for closing.
Activation of recognition of the OPEN and CLOSE input levels (maintained command).
That is to say, the board recognises the level (if, for example, with OPEN held, you press
03
STOP, when the latter is released, the automated system will continue to open). If
bled the board commands a manoeuvre only if there is an input variation.
Activation of DEAD-MAN opening (command always pressed). Releasing the OPEN command
04
will stop operation
When this function is activated, the OPEN command during opening will stop movement. If
06
no
05
parameter
is
06
If parameter
is
When this function is activated, the OPEN command during opening reverses movement. If
06
05
parameters
and
When this function is activated, the OPEN command during pause stops operation.
07
07
If parameters
and
When this function is activated, the OPEN command during pause causes closing.
08
07
If parameters
and
When this function is activated, the OPEN command during closing stops operation,
09
otherwise it reverses movement.
Activation of DEAD-MAN closing (command always pressed). Releasing the CLOSE command
10
will stop operation
When this function is activated, the CLOSE command has priority over OPEN, otherwise
11
OPEN has priority over CLOSE.
When this function is activated, the CLOSE command commands closing when released. As
12
long as CLOSE is activated, the unit stays in closing pre-fl ashing.
When this function is activated, the CLOSE command during opening stops operation, other-
13
wise the CLOSE command commands reverse immediately or when opening is completed
(see also parameter
When this function is activated, and if parameter
14
immediate closing at the end of the opening cycle (stores CLOSE). If parameters
no
are
CLOSE commands immediate closing.
When this function is activated, with the system blocked by a STOP, a next OPEN
15
moves in the opposite direction. If parameter
When this function is activated, during closing, the CLOSING SAFETIES stop and allow motion
16
to resume when they are disengaged, otherwise they immediately reverse opening.
When this function is activated, the CLOSING SAFETIES command closing when they are
17
disengaged (see also parameter
When this function is activated, and if parameter
18
opening cycle to end before executing the closing command provided by the
CLOSING SAFETIES.
When this function is activated, during closing, LOOP2 stops and allows motion to resume
19
when it is disengaged, otherwise it immediately reverses opening.
When this function is activated, LOOP2 commands closing when it is disengaged (see also
20
21
parameter
).
When this function is activated, and if parameter
21
cycle to end before executing the closing command provided by LOOP2.
When this function is activated: in case of a blackout, once electrical power has been resto-
22
red, if an OPEN command is not active the automated system recloses immediately.
LOOP 1 commands opening and, once completed, it closes if disengaged (useful in case of
23
vehicle backing-up with consecutive loops). If disabled, when LOOP 1 is disengaged, it does
not close.
B680H
10 sec
the system is ready for opening.
Y
the system is ready for closing.
06
no
are
OPEN will have no effect during opening.
08
no
are
OPEN resets the pause time
08
no
are
OPEN resets the pause time.
14
)
13
15
is
18
).
no
is
, the CLOSE command commands
no
it always closes.
17
Y
is
, the unit will wait for the
20
Y
is
, the unit will wait for the opening
17
Setting
Y
= automatic closing
no
= disabled
Y
= 2-input operation
no
= disabled
Y
= level recognition
no
03
= status variation
is disa-
recognition
Y
= active
no
= disabled
Y
= when opening it stops
no
= disabled
Y
= when opening it reverses
no
= disabled
Y
= when in pause it stops
no
= disabled
Y
= when in pause it closes
no
= disabled
Y
= stops
no
= reverses
Y
= active
no
= disabled
Y
= active
no
= disabled
Y
= closes when released
no
= closes immediately
Y
= CLOSE stops
no
= CLOSE reverses
Y
= closes at the end of
13
14
and
opening
no
= immediate closing
Y
= moves in the opposite
direction
no
= always closes
Y
= closes when disengaged
no
= immediate reverse
Y
=
closing
is disengaged
no
= disabled
Y
= closes at the end of
opening
no
= disabled
Y
= closes when disengaged
no
= immediate reverse
Y
= closes if LOOP2 is clear
no
= disabled
Y
= closes at the end of
opening
no
= disabled
Y
= active
no
= disabled
Y
= closes if LOOP1 clear
no
= disabled
when
FSW
732719 - Rev.D

Advertisement

Table of Contents
loading

Table of Contents