DL1 LED description (Red)
On
At least one of the inputs (safeties, OPEN pulse) is
engaged or active
Off
No OPEN input is active and no safety device is
engaged
DL2 LED description (Green)
On
Normally active (LED on even if there are no devices
fixed
connected)
Off
BUS-2EASY line short-circuited (flash every 2.5 sec.)
Rapid flas-
An error has been detected in the BUS-2EASY con-
hing
nection; repeat the acquisition procedure. If the error
persists, check that:
the system does not have more than one acces-
sory with the same address (see also instructions
regarding the accessories)
make sure there is no calling error (number of
devices connected is greater or less than that
stored during setup)

6. ADVANCED programming

To access ADVANCED programming, press F and, while holding it,
+
also press
:
+
when
is released, the number of the first available function
will appear
when F is also released, the value is displayed, and can be
+
-
changed using
and
pressing F again, and holding it, the name of the next parameter
will be displayed; when released, the value can be changed
+
-
using
and
once the last function has been reached, pressing F makes it
possible to either save the previously changed parameters or exit
without saving the changes; the display will go back to showing
the status of the inputs.
ADVANCED PROGRAMMING
Display Function
Opening motor power
FO
Adjusts the thrust of the motor during the opening
phase.
00
Minimum power
50
Maximum power
Closing motor power
FC
Adjusts the thrust of the motor during the closing
phase.
00
Minimum power
50
Maximum power
Pre-flashing
PF
This parameter is used to activate the flashing lamp
for 5 seconds before the selected movement.
no
disabled
OC
before each movement
CL
before each closing movement
OP
before each opening movement
PA
only at the end of the pause
Pre-flashing time
tP
Pre-flashing time expressed in seconds.
00
minimum pre-flashing
10
maximum pre-flashing
B680H
Display
Function
Sensitivity of obstacle during closing
oc
This determines the sensitivity to an obstacle before
reversing takes place.
01
Minimum sensitivity
50
Maximum sensitivity
Output 1
o1
Setting this function makes it possible to modify the
signal type of output 1, allowing high connection
flexibility with external devices.
00
Failsafe
0 1
TYPE 1 BEAM ILLUMINATION (output
active when beam closed, disabled with bar
open or paused, intermittent when moving).
Use only with output 4!
02
BAR LIGHTING TYPE 2 (fl ashing output
during opening, closing and with rod closed
or stopped. inactive with rod open or
paused).
03
Beam CLOSED
04
Beam OPEN or in PAUSE, it goes off during
closing pre-fl ashing.
05
Beam in OPENING MOVEMENT, including
pre-fl ashing.
06
Beam in CLOSING MOVEMENT, including
pre-fl ashing.
07
Beam STATIONARY
08
Beam in EMERGENCY mode
09
LOOP1 engaged
10
LOOP2 engaged
11
OPEN for E680 slave
12
CLOSE for E680 slave
13
Default
Beam RELEASED
14
Not used
40
15
Not used
16
FCA engaged
17
FCC engaged
18
Interlock
19
WARNING LAMP (on during opening and
40
pause, fl ashing when closing, off when the
automated system is closed)
20
Battery operation
Output 1 Polarity
P1
Allows setting of the output polarity:
Y
output NC
no
no
output NO
NOTE: if the output setting is
the value set to
Output 2
o2
Output 2 signal type, see "Output 1"
Output 2 Polarity
P2
Output 2 polarity, see parameter regarding "Output
1 Polarity"
00
Output 3
o3
Output 3 signal type, see "Output 1"
Output 3 Polarity
P3
Output 3 polarity, see parameter regarding "Output
1 Polarity"
Output 4
o4
Output 4 signal type, see "Output 1"
14
00
(Failsafe), keep
no
732719 - Rev.D
Default
30
04
no
03
no
19
no
01