FAAC B680H Manual page 25

Hide thumbs Also See for B680H:
Table of Contents

Advertisement

Tab. 1/g
LOGIC "CA"
AUTOMATED
OPEN A
SYSTEM STATUS
opens and closes
CLOSED
after the pause
time
WHEN OPENING
no effect
OPEN IN PAUSE
resets pause time
immediately
WHEN CLOSING
reverses to
opening
opens and closes
BLOCKED
after the pause
time
Tab. 1/h
MAINTAINED COMMANDS
LOGIC "C"
AUTOMATED
OPEN A
SYSTEM STATUS
CLOSED
opens
WHEN OPENING
no effect
OPEN
(closing inhibited)
immediately
WHEN CLOSING
reverses to
opening
BLOCKED
opens
 In brackets, the effects on the other inputs when the pulse is active
B680H
CLOSE
no effect
closes
immediately after
opening is com-
pleted
closes
no effect
closes
CLOSE
no effect
/
no effect
closes
/
closes
PULSES
STOP
FSW
no effect
no effect
(opening inhibited)
blocks
no effect
operation
blocks
resets pause time
operation
(closing inhibited)
reverses to
blocks
opening and clo-
ses after pause
operation
time
no effect
no effect
(opening and clo-
(closing inhibited)
sing inhibited)
STOP
FSW
no effect
no effect
(opening inhibited)
blocks
no effect
operation
blocks
no effect
operation
blocks
blocks
operation
operation
no effect
no effect
(opening and clo-
(closing inhibited)
sing inhibited)
25
LOOP 1
LOOP 2
opens and closes
after the pause
no effect
time
closes
immediately after
no effect
opening is com-
closes when
resets pause time
disengaged
immediately
immediately re-
reverses to
verses to opening
opening
opens and closes
no effect
after the pause
(closing inhibited)
time
PULSES
LOOP 1
LOOP 2
no effect
no effect
no effect
no effect
no effect
no effect
(closing inhibited)
(closing inhibited)
blocks
blocks
operation
operation
no effect
no effect
(closing inhibited)
(closing inhibited)
732719 - Rev.D