Table 4.8 USB Option Menu Items
NOTICE!
This product incorporates field-programmable software. In order for the product to comply
with the requirements in the Standard for Control Units and Accessories for Fire Alarm Systems,
UL 864, certain programming features or options must be limited to specific values or not
used at all as indicated in Table 4.9, Page 28.
Bosch Security Systems, Inc.
Description
To change the login password, enter the old password first, and then enter the new
password twice. The second entry confirms the new password.
Passwords must be 4-15 characters long, and are case-sensitive.
0-9, A-Z, a-z, and special characters are allowed.
Change the debugging level shown on the View Log screen.
View the debugging log for diagnostic purposes. Press any key to exit.
Return to the USB interface login screen. Press [Y] (for Yes) to exit without saving. All
configuration changes that were made are lost and are replaced with the previous
values.
Select to restore all factory default values.
When prompted, remove the plug from the CONFIG jumper pins to restart the
ITS-DX4020-G. Warning: All fields are cleared and the factory default values are
restored.
Select to save all changed values (changed values are preceded by an asterisk [*]).
Press [Y] (for Yes).
When prompted, remove the plug from the CONFIG jumper pins to restart the
ITS-DX4020-G.
Select this option to upgrade the firmware in the ITS-DX4020-G.
Refer to Section 6 Firmware Upgrade, page 35.
To change a basic parameter:
1. Press the [Enter] key repeatedly until the cursor is on the desired parameter.
2. Enter the desired value. If you do not enter a new value at the prompt, the previous
value is retained.
After all Basic parameters are reviewed, the USB main menu reappears, indicating
changed values with asterisks (*).
Refer to Table 4.10, Page 30 for basic parameters.
To change an advanced parameter:
1. Press the [Enter] key repeatedly until the cursor is on the desired parameter.
2. Enter the desired value. If you do not enter a new value at the prompt, the previous
value is retained.
After all Advanced parameters are reviewed, the USB main menu re-appears,
indicating changed values with an asterisk (*).
Refer to Table 4.10, Page 30 for advanced parameters.
Installation and Operation Guide
Configuration | en
27
F01U163066 | 01 | 2010.05