15) After filling stops, add 1/2 gallon of water to the reservoir. Do not overflow the reservoir.
16) Turn the ON/OFF lever OFF to start the drain cycle.
17) After the reservoir drains, set the ON/OFF lever to the ON position to refill the reservoir.
18) Close the cooking compartment door and set the timer for 20 minutes (ON/OFF Control Models:
set the control to ON.). The steamer heats to normal operating temperature.
19) After 20 minutes turn OFF ON/OFF controls and turn the ON/OFF lever to OFF.
20) The 3-minute drain cycle starts.
This is the final rinse of the reservoir.
21) If the reservoir drains slowly even after being descaled, turn OFF the steamer and clean the
drains with a NSF approved drain cleaner.
22) Once the scale is removed and the drain flows freely, the steamer is ready for normal operation.
B. Troubleshooting Guide
The Troubleshooting Guide is a list of symptoms of problems that may be encountered during operation.
"Problem" (left column) lists common operating problems.
"Possible Cause" (center column) lists causes of problems in order they should be checked.
"Remedy / Reference" (right column) lists fixes for problems from easiest to hardest.
"Notes" in "Remedy / Reference column are at end of Table 3-1 Troubleshooting Guide.
ATTEMPTING TO REPAIR OR CORRECT PROBLEMS REQUIRING AN AUTHORIZED SERVICE
PROBLEM
Power indicator light
does not turn ON when
ON/OFF lever is in the
ON position.
Power ON and
SteamChef does not fill
PROBLEM
Control panel power
indicator light ON, and
SteamChef does not
come up to cooking
temperature or produce
steam.
REPRESENTATIVE VOIDS WARRANTY
Table 3-1 Troubleshooting Guide
POSSIBLE CAUSE
Power turned OFF at main external
power switch.
ON/OFF lever not fully turned to the
ON position.
Inoperative controls or indicators.
Water supply to SteamChef shut OFF
Water line strainer and/or external filter
system clogged.
Gas Supply is turned OFF.
Water sensor is grounded by detergent
film, or scale.
Inoperative controls or solenoids.
Troubleshooting Guide(Continued)
POSSIBLE CAUSE
Door interlock switch not engaged.
Water supply to SteamChef shut OFF
Water line strainer and/or external filter
system clogged.
SteamChef is in the Timed Mode and
Timer is not set. (Dial Timer control
models only.)
REMEDY/REFERENCE
Turn ON power at main external power
switch.
Turn lever to the ON position.
See Note 1
Open water supply lines.
Clean water supply strainer and/or
filter system. See Yearly Maintenance
in Chapter 7
Turn gas supply ON.
Rinse water sensor assembly
thoroughly with vinegar solution, as
described in Chapter 6, Shutdown and
Cleaning Procedure.
See Notes 1 and 5
REMEDY/REFERENCE
Close door completely.
Open water supply lines.
Clean water supply strainer and/or
filter system. See Yearly Maintenance
in Chapter 7.
Change to Manual Mode or set the
Timer.
38