This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service
Representatives who are familiar with both the safety procedures, and equipment they service.
Cleveland Range, LLC assumes no liability for any death, injury, equipment damage, or property damage
resulting from use of, improper use of, or failure to use the information contained in this document.
Cleveland Range, LLC has made every effort to provide accurate information in this document, but
cannot guarantee that this document does not contain unintentional errors and omissions.
The information in this document may be subject to technical and technological changes, revisions, or
updates.
Cleveland Range, LLC assumes no liability or responsibility regarding errata, changes, revisions, or
updates.
Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to follow industry
standard safety procedures, including, but not limited to, OSHA regulations, and disconnect / lock out /
tag out procedures for all utilities including steam, and disconnect / lock out / tag out procedures for gas,
electric, and steam powered equipment and / or appliances
All utilities (gas, electric, water and steam) should be turned OFF to the equipment and locked out of
operation according to OSHA approved practices during any servicing of Cleveland Range equipment
Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to maintain up-to-date
knowledge, skills, materials and equipment.

Advertisement

loading

Summary of Contents for Cleveland SteamCraft Ultra 5 21-CET-16

  • Page 1 Statement of Responsibilities This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and equipment they service. Cleveland Range, LLC assumes no liability for any death, injury, equipment damage, or property damage resulting from use of, improper use of, or failure to use the information contained in this document.
  • Page 2 Cleveland Range, LLC 1333 East 179th St., Cleveland, Ohio, U.S.A. 44110 Ph: 1-216-481-4900 Fx: 1-216-481-3782 Visit our Web Site at www.clevelandrange.com...
  • Page 3: Mechanical Timer

    CLEVELAND RANGE 21CET16 SEQUENCE OF OPERATIONS Mechanical Timer 1. Supply power is sent to the primary of the main transformer. • 115 VAC is sent from the secondary of the main transformer to the on/off rocker, 1. To turn the unit on, depress the red on/off rocker switch.
  • Page 4 7. After the water level drops below the high probe for 5 seconds 115 VAC is sent to the FILL terminal again. 8. The red on/off rocker switch is depressed and the unit is turned off. • 115 VAC is removed from the timer and heat circuits. •...
  • Page 6 STEAMCRAFT 5.1 MECHANICAL TIMER H2 H4 REMOVED W / OPTIONAL DOOR SWITCH ( SCS ) H2 H4 208/240 JUMPER POSITION LT BLU FOR 480 V OPERATION LT BLU WHT/BLK CUSTOMER CONNECTION WHT/RED HEATER WHT/RED ELEMENTS WHT/RED WHT/BLK WHT/GRA WHT/BLU FILL COND WHT/RED PARTS LIST...
  • Page 9 STEAMCRAFT 5.1 ELECTRONIC TIMER CUSTOMER CONNECTION 380/415V 3Ø W / NEUTRAL CONTACTORS FUSEBLOCK TO H1 TO H4 HEATING ELEMENTS CONTACTORS CUSTOMER CONNECTION FUSEBLOCK DRYING ELEMENT H1 PRIMARY TRANSFORMER RESET CIRCUIT BREAKER X2 SECONDARY 120V DESCALE TIMER DESCALE INDICATOR & RESET SWITCH FILL VALVE POWER ON 3 MIN TIMER...
  • Page 11 Steamer won't PROBLEM: steam 21CET8 21CET16 21CEA10 Is the red light Steamer won't Is there supply Supply power to voltage to the steam. the steamer. primary of the transformer? Is there 115 VAC at STEAMER Is there water Replace the the secondary of WON'T FILL in the sight...
  • Page 12 Steamer wont fill. PROBLEM: 21CET8 21CET16 24CEA10 Is there supply Supply power to voltage to the Steamer wont the steamer. steamer? fill Is there water Supply cold water to the to the steamer. steamer? Is there 120 VAC Replace the on/off between the H and N rocker switch.
  • Page 13 PROBLEM: 21CET8, 21CET16, 24CEA10 Electronic timer displays "PAUS" and won't count down Timer displays "paus" and won't count down Is steam heating the cooking cabinet above 192 Steamer degrees (the set won't steam temp of the thermo-switch)? Does the timer Replace the count down when Replace the...
  • Page 14 PROBLEM: 21CET8 21CET16 24CEA10 Steamer overfills Steamer overfills. (Water sprays into the (Water sprays into cooking cooking cabinet) cabinet) Start Does Does Does There is an the rise in the water the water rise in the the water level in the obstruction in the level in the sight glass sight glass when steam...
  • Page 15 PROBLEM: 21CET8 Steamer won't 21CET16 stop steaming 24CEA10 Steamer won't stop steaming with door open Steamer will steam constantly in the Is the manual position. Put timed/manual switch the timed/manual in the timed position switch in the timed with no time on the position with no time on timer? the timer.
  • Page 16 Problem: 21CET16 Steamer won't preheat Steamer won't preheat This steamer is not equiped with a Is the preheat timed/manual thermostat. The Does the steamer switch in the timed postion timed manual have a preheat with time on it or in the switch must be in thermostat manual...
  • Page 17 Descaling Procedure-SteamCraft Ultra and Gemini Series 6. Let the descaler soak in generator for How Much DISSOLVE to Use approximately one hour: Model Dissolve 7. After one hour, turn the unit power Ultra 3 1/2 Gallon Off: This will drain and rinse the generator Ultra 5 1 Gallon for about 3 minutes.