LIGHTING INSTRUCTIONS
1) CLOSE THE COOKING COMPARTMENT DOOR.
2) TURN THE ON/OFF LEVER/SWITCH CLOCKWISE TO THE ON POSITION.
RESERVOIR WILL FILL WITH WATER (ABOUT 1 MINUTE).
SPARK WILL INITIATE, AND MAIN GAS VALVE WILL OPEN FOR 4 SECONDS.
IF THE UNIT FAILS TO LIGHT WITHIN 4 SECONDS GAS VALVE WILL CLOSE AND
LOCKOUT AND A CONTINUOUS BUZZER WILL SOUND.
3) SYSTEM MAY BE RESET MANUALLY BY TURNING THE ON/OFF LEVER/SWITCH OFF
FOR 5 MINUTES AND BACK ON.
SHUTDOWN INSTRUCTIONS
1) TURN OFF THE ON/OFF LEVER/SWITCH.
2) WAIT FOR THE 3-MINUTE DRAIN RINSE CYCLE TO RUN.
3) TURN OFF THE MAIN EXTERNAL POWER SWITCH.
4) TURN OFF THE MAIN MANUAL GAS VALVE.
B. Burner Ignition Test
NOTICE: Perform this test before the Startup Procedure in Chapter 5, "Operating Tests and Final
Checkout Procedure."
1. Lighting Instructions and Test of Direct Spark Ignition System
1) If not already done:
Leak test the water supply lines.
Leak test the gas supply lines.
Test the drain lines. Pour about a quart of water through the KleanShield drain and
check that water flows out the drain and drainpipe
2) Turn the Main External Power Switch OFF.
3) Open the cooking compartment door.
4) Control Panel Settings:
ON/OFF Lever: OFF.
TIMED/MANUAL Switch: TIMED.
5) Turn ON the power to the SteamChef at the Main External Power Switch.
The 3-minute drain rinse cycle starts. Water flows from the drain and stops after 3 minutes.
6) Turn ON the power to the SteamChef at the ON/OFF lever.
a) The Timer display (Keypad control), OR the green light (Timer and On/Off control) lights.
b) The water reservoir begins to fill with water.
c) The burner does NOT light.
d) Close the cooking compartment door.
e) After the cooking compartment door is closed and the water reservoir has filled to the
operating level, the igniter spark initiates and the automatic gas valve opens for 4 seconds.
If the SteamChef burner does NOT light within 4 seconds: the safety circuit in the
igniter control de-energizes the system, closes the automatic gas valve, and locks out
the ignition module and a continuous buzzer will sound. Go to f).
If the burner lights: The cooking compartment temperature rises to the operating
temperature. Go to g).