To Preheat The Steamchef; High Limit Lockout - Cleveland SteamChef 22CGT3.1 Operation Installation Maintenance Manual

Hide thumbs Also See for SteamChef 22CGT3.1:
Table of Contents

Advertisement

The following START-UP SUMMARY is for quick reference ONLY. For safe operation and use of this
equipment, the operator must comply with all safety and operating instructions in this manual.
LIGHTING INSTRUCTIONS
1) CLOSE THE COOKING COMPARTMENT DOOR.
2) TURN THE ON/OFF LEVER/SWITCH CLOCKWISE TO THE ON POSITION.
RESERVOIR WILL FILL WITH WATER (ABOUT 1 MINUTE).
SPARK WILL INITIATE, AND MAIN GAS VALVE WILL OPEN FOR 4 SECONDS.
IF THE UNIT FAILS TO LIGHT WITHIN 4 SECONDS GAS VALVE WILL CLOSE AND
LOCKOUT AND A CONTINUOUS BUZZER WILL SOUND.
3) SYSTEM MAY BE RESET MANUALLY BY TURNING THE ON/OFF LEVER/SWITCH OFF FOR
5 MINUTES AND BACK ON.
SHUTDOWN INSTRUCTIONS
1) TURN OFF THE ON/OFF LEVER/SWITCH.
2) WAIT FOR THE 3-MINUTE DRAIN RINSE CYCLE TO RUN.
3) TURN OFF THE MAIN EXTERNAL POWER SWITCH.
4) TURN OFF THE MAIN MANUAL GAS VALVE.
F. To Preheat the SteamChef
Preheating the SteamChef helps ensure productivity and consistency. Preheat before cooking, and
reheat as needed between batches of food.
BEFORE PREHEATING inspect and clean the compartment. After preheating, the compartment will be
too hot to inspect and clean safely.

To preheat the SteamChef:

a. Turn the SteamChef ON 15 minutes before cooking to allow time for the water reservoir to fill and
SteamChef to heat:
1) Close the SteamChef door.
2) Select Timed mode.
3) Set the Timer to 0.
4) Turn ON the ON/OFF lever.
b. The SteamChef heats to the operating temperature.
G. High Limit Lockout
This SteamChef has a High Limit Lockout to protect the SteamChef from overheating.
1. If the SteamChef reaches the high limit temperature, the RESET light turns ON, a buzzer sounds
continuously, and the burner shuts OFF.
The SteamChef must be reset before cooking can continue.
2. If the SteamChef overheats and locks out while cooking, open the door and check if there is water in
the reservoir.
If there is no water in the reservoir:
a. Turn OFF the SteamChef
b. Wait for the SteamChef to cool
c. Clean the water level probes
d. Reset the High Limit Lockout (See Step 3.)
e. Restart the SteamChef.