Temporarily Overriding The Tou Scheduler; Disabling The Tou Scheduler In Anticipation Of A Grid Outage; Access Installer Configuration Tool (Optional) - Generac Power Systems XVT076A03 Installation And Owner's Manual

Pwrcell
Hide thumbs Also See for XVT076A03:
Table of Contents

Advertisement

Commissioning
Rebus Beacon
Enable
Disable
Mod. Settings
Calibrate CTs
Cancel
RCPn: 00010003XXXX
< EXIT
SCROLL > NEXT • SELECT
Figure 6-22. Disabling Beacon (2 of 3)
4. See
Figure
6-23. The status line on the Beacon
device page will read Disabled.
NOTE: The system will remain in the current system
mode until the mode is changed manually or the sched-
uler is re-enabled.
REbus Beacon
TOU Scheduler
disabled
To enable scheduler,
press center button
and select "Enable".
Figure 6-23. Disabling Beacon (3 of 3)

Temporarily Overriding the TOU Scheduler

The scheduler can be temporarily overridden at any time
without disabling it. A manual override will apply until the
next regularly scheduled system mode change.
To temporarily override the scheduler:
1. Navigate to the system home page.
2. Press the center button.
3. Select the desired temporary system mode.
When the scheduler has been overridden:
Temporary Override will display on the home page,
alternating with the words Scheduler Active and
the name of the current system mode.
See
Figure
6-24. Running, Overridden will display
on the Beacon device page.
32
Menu
Confirm
010117
010118
REbus Beacon
TOU Scheduler
running, overridden
Next Change:
To:
Schedule:
Figure 6-24. Overriding Scheduler
The countdown timer on the Beacon device page
will indicate the remaining time until the next mode
change.
After the next scheduled mode change, the scheduler will
resume normal operation.
Disabling the TOU Scheduler in Anticipation of a
Grid Outage
In the event of an impending storm and potential outage,
top off the battery by disabling the scheduler and switch-
ing the system mode to priority backup or clean backup
mode.
To disable the TOU Scheduler:
1. Navigate to the Beacon device page and disable
the scheduler. See
more information.
2. Navigate to the system home page and change the
system mode to a backup-only mode, such as Pri-
ority Backup or Clean Backup.
3. Once the emergency has passed, re-enable the
scheduler. See
Disabling Beacon TOU
information.
NOTE: If Priority Backup mode is not listed with the other
system modes, the system installer may have removed
the mode to comply with utility rules. Some utilities do not
permit a battery to charge from the grid.
Access Installer Configuration Tool
(optional)
The Installer Configuration Tool allows configuration and
provisioning of Generac PWRcell systems from a smart-
phone or laptop. The interface allows installers to config-
ure basic settings, set inverter compliance, generate a
compliance report, and understand system performance.
The interface is only available on Generac PWRcell sys-
tems with a REbus Beacon installed. Close proximity to
the Beacon is required for use. It is not possible to
access this tool remotely. 45 minutes after being acti-
vated, the Beacon's WIFI signal will time out and may
need to be reactivated.