3. INSTALLATION
The power cable must terminate with a plug to connect to the electrical
panel having a corresponding Residual Current Circuit Breaker with Over
Current Protection.
The equipment is not supplied with a power plug.
The coupling between plug and socket must be such that the earth
conductor is connected first and disconnected last and must have the
right dimensions for the rated current. Plugs and sockets for industrial use
of the type CEE17 are suitable or those which satisfy European norm EN
60309.
The thermal circuit breaker must be calibrated to the total rated current
and the magnetic circuit breaker calibrated to the rated current (In the
case of ovens this is only slightly higher than rated current), while the
differential device must be calibrated to the 30 mA current (see Annex A).
The electrical socket must be easily accessible and must not need moving
after equipment installation. The distance between the equipment and the
socket must be sufficient to avoid stretching the power cable
The power cable must never be trapped under the feet or
wheels of the equipment
If the Power cable is damaged it must be replaced by
customer support or by a qualified service engineer so as to avoid
any risk.
The manufacturer does not accept responsibility for damage
caused by failure to observe the abovementioned norms.
For the position of the electrical power connections, see Annex B.

3.6. Emissions from cooking appliances

ATTENTION! Proceed with the installation of the oven
according to the norms defined by current legislation in the country
concerning the installation of this type of oven so as to guarantee
the sustainability of a healthy working environment. For more
information it is recommended that specific norms be consulted.