Service the PA-5200 Series Firewall
STEP 6 |
Install the replacement drive in the drive carrier.
1. Place the failed drive next to the replacement drive with the connectors facing the same
direcon.
2. Remove the four screws that hold the failed drive in the carrier and remove the drive
from the carrier.
3. Install the replacement drive in the carrier and secure it using the four screws you
removed from the failed drive.
The illustraon shows an SSD system drive and an HDD log drive; the procedure to swap
the drive is the same for both.
STEP 7 |
Install the replacement drive in the firewall.
1. Ensure that the drive carrier lever is in the open posion; if it is not, press the ejector
buon on the drive carrier to release the lever and pull it out unl it is fully open.
2. Slide the replacement drive and carrier assembly into the empty drive bay unl it is about
1/4" (.6cm) from being fully inserted.
3. Before fully inserng the drive carrier, ensure that the lever aaches to the locking
mechanism on the firewall and then close the lever to seat the carrier.
STEP 8 |
Choose from the following two installaon procedures based on your findings in 5:
• If the replacement drive is the same model number as the failed drive, connue to 9.
• If the replacement drive is a different model number than the failed drive, skip to 10.
PA-5200 Series Next-Gen Firewall Hardware Reference